beautypg.com

Enerpac PME-Series User Manual

Page 5

background image

4.

Replace the fill plug.

5.

DISPOSE OF USED OIL PROPERLY.

6.3 Cleaning the Reservoir

The reservoir can be removed for cleaning, and should be
cleaned at least once a year.

1.

Remove vent/fill plug from reservoir. Tip the pump until all old
oil has drained out.

2.

DISPOSE OF USED OIL PROPERLY.

3.

You will need to remove the yellow shroud to get at the screws
that hold the pump to the reservoir. Use an Allen wrench to
remove the six screws securing shroud to the reservoir.

4.

Disconnect wire(s) from solenoid valve. Mark wires before
disconnecting them from the 4-way valve.

5.

Lift shroud from reservoir. DO NOT remove the foam
insulation. Use care to avoid damaging wires or pulling wire
connections off terminals.

6.

Remove 8 screws holding pump to reservoir.

7.

Lift pump from reservoir using care to avoid damaging pick-up
screens.

8.

Remove gasket and discard.

9.

Thoroughly clean the reservoir with solvent. Never use water.

10. Use a soft bristle brush to clean intake screens. Rinse with

solvent.

11. Install a new gasket.
12. Position the coverplate on the reservoir. Make certain that the

gasket is visible all the way around the coverplate.

13. Secure pump to reservoir.
14. Place shroud over motor with shroud handle facing valve side

of pump.

15. Install the six mounting screws.
16. Reconnect wire(s) to solenoid valve.
17. Before reinstalling the heat exchanger, use compressed air to

blow dirt out of the heat exchanger.

18. Fill reservoir to inch below the vent/fill opening with new

Enerpac hydraulic oil. Reservoir capacity is 0.75 gallon (2.8
liters).

7.0 TROUBLESHOOTING (SEE CHART)

If your pump requires repair work, contact your Authorized
Enerpac Service Center.

Symptom

Motor current draw is excessive.

Noisy pump operation.

Pump fails to maintain pressure.

Low oil output.

Pump builds pressure slowly
or erratically.

Pump is overheating.

Possible Cause

1. Defective motor.

2. By-pass valve malfunction.

3. Damaged or worn piston blocks.

1. Piston block piston sticking. Springs or

balls damaged.

1. Oil leaking from one or more

components within the reservoir.

1. Pump component parts leaking.

2. By-pass valve may be malfunctioning.

3. Oil intake screens on piston blocks may

be clogged with debris.

4. Low oil level.

1. Internal leakage in valve.

1. Nylon tubing to heat exchanger is

disconnected

2. Thermostat malfunctions

Solution

1. Remove the motor. Test and replace if necessary.

2. Inspect and test the by-pass valve if required. Valve is preset. If

damaged or incorrectly set, replace.

3. Test and inspect the piston blocks. Replace if necessary.

1. Remove the piston blocks. Inspect and replace as required. Each

piston block is non-serviceable.

1. Remove the pump from the reservoir and perform the back

pressure test. Contact Enerpac for test procedure.

1. Perform the back pressure test to isolate leaks.

2. Test and inspect by-pass valve. Replace and set if necessary.

3. Inspect intake screens. Flush all components of contamination.

Replace damaged components.

4. Fill reservoir to proper level.

1. Disassemble valve and replace worn or failed parts.

1. Reconnect nylon tubing under pumping unit. Tubing will click into

place when it is properly connected.

2. Replace the thermostat.

TROUBLESHOOTING CHART

REFER TO TORQUE WRENCH INSTRUCTIONS FOR WRENCH OPERATING PROCEDURE.

5