Chapter 4: installation, Site requirements, Unpacking the drive components – ElmoMC Gold Line Digital Servo Drives-Gold Whistle User Manual
Page 22: Chapter 4, Installation
![background image](/manuals/558337/22/background.png)
Gold Whistle Installation Guide
MAN-G-WHIIG (Ver. 1.208)
22
Chapter 4:
Installation
The Gold Whistle must be installed in a suitable environment and properly connected to its
voltage supplies and the motor.
4.1. Site Requirements
You can guarantee the safe operation of the Gold Whistle by ensuring that it is installed in an
appropriate environment.
Feature
Value
Ambient operating temperature
0 °C to 40 °C (32 °F to 104 °F)
Maximum non-condensing humidity 90%
Operating area atmosphere
No flammable gases or vapors permitted in area
Models for extended environmental conditions are available.
Caution:
The Gold Whistle dissipates its heat by convection. The maximum ambient
operating temperature of 40 °C (104 °F) must not be exceeded.
4.2. Unpacking the Drive Components
Before you begin working with the Gold Whistle, verify that you have all of its components, as
follows:
•
The Gold Whistle servo drive
•
The Elmo Application Studio (EAS) software and software manual
The Gold Whistle is shipped in a cardboard box with Styrofoam protection.
To unpack the Gold Whistle:
1.
Carefully remove the servo drive from the box and the Styrofoam.
2.
Check the drive to ensure that there is no visible damage to the instrument. If any damage
has occurred, report it immediately to the carrier that delivered your drive.