IV.

Maintenance

A) Cleaning

The nozzle should be flushed thoroughly after each use. This is
accomplished by flowing the nozzle with a clean water source for both
water and foam inlets. Ensure the nozzle is set to the largest
proportioning rate.

B) Pilot Assembly


















Figure 5 - Pilot Valve Assembly


1. Using a

5

/

32

” Allen wrench, remove the four screws that retain the flood

plate.

2. With the aid of a pair of channel lock pliers, remove the pilot valve

assembly by turning it counter clockwise.

Caution:

Do not allow the piston head and baffle head to turn. If necessary, use a
strap wrench to secure it while moving the pilot valve assembly.


3. Using an air nozzle and pressurized air source, blow through the holes

in the spring adjustment nut to remove any small debris.

Screws

Flood Plate

Baffle Head

Assembly

Pilot Valve Port

Piston Head

Pilot Valve

Spring Adjustment Nut

This manual is related to the following products: