beautypg.com

Common problems – B&B Electronics PCMCIA 232PCC2 User Manual

Page 14

background image

Documentation Number 232PCC23799 Manual

13

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353-91-792444 – Fax +353-91-792445


Example 4

DSP100EN.EXE

(s0,b300,i3,wd8)


In example 4, the Enabler will configure the 232PCC2 in socket 0
with a base address of 300H and IRQ 3 using a configuration
memory window at segment D800. The 232PCC2's interrupt status
register will be enabled and the BIOS equipment list will not be
updated.

Example 5

DSP100EN.EXE

(s0,b300,i5,r)


In example 5, the Enabler will release the configuration used by the
232PCC2 in socket 0 using a configuration memory window at
segment D000. The base address and IRQ parameters are ignored
and may be omitted.

Example 6

DSP100EN.EXE

(s1,r,wcc)


In example 5, the Enabler will release the configuration used by the
232PCC2 in socket 1 using a configuration memory window at
segment CC00.

Common Problems

Identifying the 232PCC2

The 232PCC2 is identified as a DSP-100 when installed.


Memory Range Exclusion

The Enabler requires a region of high DOS memory when

configuring a 232PCC2. This region is 1000H bytes (4KB) long and
by default begins at address D0000H (the default address may be
changed using the "W" option). If a memory manager such as
EMM386, QEMM, or 386Max is installed on the system, this region
of DOS memory must be excluded from the memory manager's
control. Consult the documentation provided with the memory
manager software for instructions on how to exclude this memory
region.