Det-Tronics X7050 xWatch Industrial Video Surveillance Camera User Manual
Page 8
3.1
95-8600
6
WIrIng PrOCEDurE
CautIon
Power must not be applied to the device while
opening the housing or while plugging in or
removing the module.
1. Disassemble the enclosure by turning the housing
cover counterclockwise. See Figure 5 for an
illustration of the camera assembly.
2. Carefully remove the camera module.
3. Connect the external wiring to the screw connectors
marked A-, B-, C-, and D- on the camera terminal
block. See Figure 6.
Important
Do not test any wiring connected to the camera
with a meg-ohmmeter. Disconnect wiring at
the camera before checking system wiring for
continuity.
4. Check all field wiring to be sure that the proper
connections have been made.
5. Using the index pin as a guide, install the camera
module on the terminal block.
6. Re-assemble the device housing.
7. Make the final sighting adjustments and ensure that
the mounting bracket hardware is tight.
QUICK CONNECT PLUG (4)
POWER + (B)
VIDEO + (D)
POWER – (C)
VIDEO – (A)
A2365
INDEX PIN
Figure 6—xWatch camera Wiring terminal block
WIRING TERMINAL BLOCK
INDEX PIN
O-RING (2)
HOUSING COVER
CAMERA MODULE
TERMINAL CAP
A2366
QUICK CONNECT PLUG (4)
Figure 5—exploded view of xWatch camera