6
Temperature
RBC1-50
Air Atmosphere
RBC1-50
Nitrogen Atmosphere
Time to Temperature
25
°
C - 80
°
C
(approximate minutes with
25
°
C - 125
°
C
no live load)
(1)
25
°
C - 150
°
C
25
°
C - 260
°
C
4
10
14
34
4
10
14
30
Recovery Time to 125
°
C with door open 1 Min.
>1 Min.
>1 Min.
Temperature Uniformity at
(2)
125
°
C*
260
°
C*
<±1°C
±1°C
<±1°C
±1°C
Operating Temperature Range
(Based on 25
°
C ambient, and dampers fully open)
50° - 260°C
15° - 260°C
Control Stability
(3)
±0.5°C per 5°C
∆
Repeatability
±0.5°C
Cooldown Time 125° - 60
°
C
40 Min.
11 Min.
Dissipation/Mean Temperature Rise
(4)
80°C
125°C
150°C
800 Watts/4°C
1,300 Watts/6°C
1,400 Watts/6°C
(1)
Time to temperature will be slightly longer for lower voltages due to heater kW derating (empty oven).
(2)
Figures are based on a nine-point survey in an empty oven. Uniformity can vary slightly depending
on unit and operating conditions.
(3)
∆
In control stability figures represent the change in ambient temperature.
(4)
Dissipation is reduced by 17% on 50-Hertz operation. Temperature gradient/mean temperature rise is
with an evenly distributed live load.
Note: Testing performed on 240V-1PH-60HZ.