7.2. Error Messages and Alarm
Table 4 lists the more common error messages, possible problems and remedies.
Table 4. Error Messages and Next Steps.
Alarm Status
Possible Problem
Next Step
HI LIMIT LED ON
Problem with thermocouple
High Limit setpoint has
been exceeded.
Once the problem has corrected, press
RESET.
DEV HOLD LED flashing
Oven temperature has not
entered (or dropped out of) the
Auto Hold band and the soak
timer has stopped
Program a slower ramp rate or, if oven
is not heating, check heater circuit.
Top PV displays OPEN
Control thermocouple is
disconnected or broken
Repair or replace the thermocouple.
HLPV displays OPEN
High Limit thermocouple is
disconnected or broken
Repair or replace the thermocouple.