3

Temperature

Model

LND 1-42

LND 2-11

LND 2-24

Time to Temperature

25

°

C - 100

°

C

(approximate minutes with

25

°

C - 200

°

C

no load)

25

°

C - 343

°

C

6
25
56

5
14
32

3
12
30

Recovery Time Door Open 1 Min.

100

°

C

(approximate minutes with

200

°

C

no load)

343

°

C

<1
3
10

<1
2
7

<1
2
4

Temperature Uniformity at

100

°

C*

200

°

C*

343

°

C*

±1

°

C

±2

°

C

±3

°

C

±1

°

C

±2

°

C

±3

°

C

±1

°

C

±2

°

C

±3

°

C

Minimum Operating Temperature**

with water cooling

(Approximate w/20 C ambient)

without water cooling

55

°

C

97

°

C

55

°

C

100

°

C

60

°

C

110

°

C

Control Stability

±0.3

°

C

±0.3

°

C

±0.3

°

C

Repeatability

±0.5

°

C

±0.5

°

C

±0.5

°

C

Cooldown Time**

343 - 60

°

C

(approximate minutes with no load)

30

35

45



* Figures are based on actual tests in an empty oven. Uniformity can vary slightly depending on unit

and operating conditions.

** 60

°

F Supply water temperature at 120 GPH for LND1-42, 210 GPH for LND2-11 and LND2-24.

Minimum operating temperature is also affected by inert gas flow rate and temperature.