7.

Troubleshooting

7.1. Troubleshooting Error Messages and Alarms

Table 3 lists the more common error messages, the possible problems and remedies.

Table 2. Error Messages and Next Steps.
Alarm Status

Possible Problem

Next Step

Hi-Limit LED flashing

Problem with thermocouple

Hi-limit setpoint has been
exceeded.

Once the problem has corrected,
press Reset.

Soak LED flashing

Oven temperature has not
entered (or dropped out of) the
soak band and the soak timer
has stopped

Program a slower ramp rate or if
oven is not heating check heater
circuit.

Top LED displays
OPEN and lower LCD
displays CONTROL
SENS ERR

Control thermocouple is
disconnected or broken

Repair or replace the thermocouple.

Lower LCD displays HI
LIM SENS ERR

Hi limit thermocouple is
disconnected or broken

Repair or replace the thermocouple.

Lower LCD displays
HIGH LIMIT ALARM

Hi limit temperature setpoint
has been exceeded

Determine if:

the setting is too close to the
setpoint

the SSR is defective

calibration is incorrect



The lower LCD intermittently display
HL Temp. This is not an
error message, but the Hi limit thermocouple temperature
reading.

7.2. Troubleshooting Symptoms

Table 4 lists symptoms, probably causes and suggested remedies.


The circuit board mounted on the control panel has three status
LED indicators to help troubleshoot if the oven is not heating:

If LED 1 is not lit, check 2F and 3F (control fuses), or power

switch.

If LED 1 and LED 3 are lit but not LED 2, check high limit

(and optional door switch, if installed).

If all three LEDs are lit, check 1F and 4F (heater fuses), SSR,

heater, and heater relays.