Troubleshooting, Troubleshooting error messages and alarms, Troubleshooting symptoms – Despatch LAC2-12-6 User Manual
Page 34: Table 2. error messages and next steps
T
ROUBLESHOOTING
LAC Series Oven Owner
’s Manual
34
Version 106
Copyright © 2011 by Despatch Industries.
All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.
7.
Troubleshooting
7.1. Troubleshooting Error Messages and Alarms
Table 3 lists the more common error messages, the possible problems and remedies.
Table 2. Error Messages and Next Steps.
Alarm Status
Possible Problem
Next Step
Hi-Limit LED flashing
Problem with thermocouple
Hi-limit setpoint has been
exceeded.
Once the problem has corrected,
press Reset.
Soak LED flashing
Oven temperature has not
entered (or dropped out of) the
soak band and the soak timer
has stopped
Program a slower ramp rate or if
oven is not heating check heater
circuit.
Top LED displays
OPEN and lower LCD
displays CONTROL
SENS ERR
Control thermocouple is
disconnected or broken
Repair or replace the thermocouple.
Lower LCD displays HI
LIM SENS ERR
Hi limit thermocouple is
disconnected or broken
Repair or replace the thermocouple.
Lower LCD displays
HIGH LIMIT ALARM
Hi limit temperature setpoint
has been exceeded
Determine if:
the setting is too close to the
setpoint
the SSR is defective
calibration is incorrect
The lower LCD intermittently display HL Temp. This is not an
error message, but the Hi limit thermocouple temperature
reading.
7.2. Troubleshooting Symptoms
Table 4 lists symptoms, probably causes and suggested remedies.
The circuit board mounted on the control panel has three status
LED indicators to help troubleshoot if the oven is not heating:
If LED 1 is not lit, check 2F and 3F (control fuses), or power
switch.
If LED 1 and LED 3 are lit but not LED 2, check high limit
(and optional door switch, if installed).
If all three LEDs are lit, check 1F and 4F (heater fuses), SSR,
heater, and heater relays.