beautypg.com

Behringer MDX1400 User Manual

Page 10

background image

10

AUTOCOM PRO MDX1400

15

The SC FILTER switch activates a highpass filter in the sidechain path and thus limits the influence of

low frequencies on the AUTOCOM PRO’s control processes.

16

The 12-digit GAIN REDUCTION meter indicates how effectively the gain is reduced by the compressor,

within a range from 1 to 30 dB.

17

The 12-digit INPUT/OUTPUT LEVEL meter informs you – depending on the setting of the I/O METER

switch – about the current input or output level, within a range from -30 to +18 dB. When the switch is

set to IN (engaged), the meter reads the input level, when it is OUT (not engaged), the output level is

displayed. The meter is referenced to the operating level (-10 dBV or +4 dBu) adjusted with the

OPERATING LEVEL switch.

2.3 Dynamic Enhancer Section

18

Fig. 2.4: Control elements of the dynamic enhancer section

18

The PROCESS control sets the available amount of enhancement between Off and 6. Dynamic

enhancement allows you to replenish any high frequencies lost through the compression process for

absolutely natural sounding dynamics control. Enhancement is only added when compression is taking

place.

2.4 Rear Panel Control Elements Of The AUTOCOM PRO

20

19

23

22

26

25

24

21

Fig. 2.5: Control elements of the rear panel

19

SERIAL NUMBER. Please take the time to fill out and return the warranty card within 14 days from the

date of purchase, so as to be entitled to benefit from our extended warranty. Or use our online

registration option available on the Internet at www.behringer.com.

20

FUSE HOLDER / VOLTAGE SELECTOR. Please make sure that your local voltage matches the

voltage indicated on the unit, before you attempt to connect and operate the AUTOCOM PRO. Blown

fuses may only be replaced by fuses of the same type and rating.

21

MAINS CONNECTION. Use the enclosed power cord to connect the unit to the mains. Please also note

the instructions given in the “INSTALLATION” chapter.

2. CONTROLS