beautypg.com

Despatch Protocol Plus Controller (Heat/Cool) User Manual

Page 39

background image

33

Autostart

Menu Item

Display

Default Range

Setting

Enable Autostart

Auto Start Enable

No

No, Yes

Sunday mode

Auto Start Sun Mode

Off

Off, Manual, Timer, Pro-1 to Pro-8

Sunday time

Auto Start Sun Time

00:00

00:00 to 23:59

Monday mode

Auto Start Mon Mode

Off

Off, Manual, Timer, Pro-1 to Pro-8

Monday time

Auto Start Mon Time

00:00

00:00 to 23:59

Tuesday mode

Auto Start Tue Mode

Off

Off, Manual, Timer, Pro-1 to Pro-8

Tuesday time

Auto Start Tue Time

00:00

00:00 to 23:59

Wednesday mode

Auto Start Wed Mode

Off

Off, Manual, Timer, Pro-1 to Pro-8

Wednesday time

Auto Start Wed Time

00:00

00:00 to 23:59

Thursday mode

Auto Start Thu Mode

Off

Off, Manual, Timer, Pro-1 to Pro-8

Thursday time

Auto Start Thu Time

00:00

00:00 to 23:59

Friday mode

Auto Start Fri Mode

Off

Off, Manual, Timer, Pro-1 to Pro-8

Friday time

Auto Start Fri Time

00:00

00:00 to 23:59

Saturday mode

Auto Start Sat Mode

Off

Off, Manual, Timer, Pro-1 to Pro-8

Saturday time

Auto Start Sat Time

00:00

00:00 to 23:59



PID

Menu Item

Display

Default

Range

Setting

Display units

PID Temp Unit

°C

°C or °F

Proportional band

PID PB(H)

6°C

1 to 56°C (1 to 100°F)

Integral reset

PID I(H) Rep/min

2

0 to 100 seconds/repeat

Derivative Rate

PID D(H) in sec

0

0 to 500 seconds

AutoTune

PID AutoTune

Disable

Disable, Enable

Proportional Band

PID PB(C)

6°C

1 to 56°C (1 to 100°F)

Integral reset

PID I(C) Rep/min

2

0 to 100 seconds/repeat

Derivative Rate

PID D(C) in sec

0

0 to 500 seconds

Heat Offset

PID Heat Offset

0°C

-6 to 6

°

C

(-11 to 11

°

F

)

Cool Offset

PID Cool Offset

0°C

-6 to 6

°

C

(-11 to 11

°

F

)