1 dva t8 and dva t12 – line array module, 1 compact view, 2 expanded view – dB TECHNOLOGIES DVA NETWORK 1.2 Device Plugins Manual User Manual
Page 3: Dva t8 and dva t12, Line array module, Compact view, Expanded view, Dva t8 and dva t12 – line array module
2/17
Rev 1.0
1
DVA T8 and DVA T12
– Line Array Module
1.1 Compact View
Comm: Green indicates that communication between speaker and Control is working. In case of
communication error the indicator becomes red.
Eq. Sync: Green indicates that actual device Eq. is synchronized with the Group. Eq showed in the DVA
Network software.
Status: This indicator shows the device status. Green indicates normal operation; when it becomes red, an
error condition is occurring.
MUTE: The device can be muted by selecting the button; it turns red when enabled.
SOLO: Allows to listen to only to the selected device. Other devices will be automatically muted.
Light indicators under Speaker Image: shows status of each audio way (Midrange, tweeter and woofer):
Green: audio level of the relevant channel exceeds -40dBfs (decibel full. scale, 0dBfs = maximum
power delivered by channel amplifier)
Red: amplifier delivers maximum power and limiter is active.
Vu-meter bars:
left bar (green) indicates the input signal level (in dBu)
right bar (red) indicates the limiter compression level (in dB) (average of the 3 audio ways)
An indicator located above compressor average level becomes red when maximum signal level allowed on
preamplifier input is reached.
1.2 Expanded View
MF-HF-LF Panels: show advanced parameters for each audio way (Midrange, Tweeter and Woofer).