Safe Operating Practices
Read and understand all procedures and safety instructions before
using the Micro Duct Installation Kit. Observe all safety information on
this page and note specific safety requirements as explained by
procedures called out in this manual. Failure to follow these instructions
could result in serious personal injury, property damage or death.
A. WORK AREA SAFETY
1. Wear personal protective equipment: hard hat, safety glasses,
safety shoes, and leather work gloves.
2. The safe operation of this equipment requires that the operators be
on stable footing.
3. Stay clear of cables or lines under tension.
4. Stay clear of pressurized line and conduit.
5. Stay out of manhole while blower is in use.
6. Use the blower only for its intended purpose. Do not use the
tractor drive without the air block to push or pull cable.
7. Do not place cable reel too close to unit. Place the reel far enough
away from the unit to ensure proper control.
8. Do not tamper with relief valves or pressure reducing valves.
9. Place cable grip on end of conduit to catch cable carrier and cable.
10. Keep hands away from tractor drive while blower is in operation.
B. HYdRAuLIC dEvICES
Escaping fluids under pressure can penetrate the skin and cause
serious personal injury. Observe the following precautions to avoid
hydraulic hazards:
1. Tighten all connections before applying pressure. Relieve pressure
when connecting or disconnecting hoses when servicing the unit.
2. Check for leaks with a piece of cardboard. Do not use your hands!
3. Do not exceed working pressure of hydraulic hoses.
4. Visually inspect hoses regularly and replace if damaged.
C. PNEumATIC dEvICES
The Micro Duct Installation Kit is a pneumatic device, using pressurized
air to project cable at high velocities. Please observe the following
precautions when operating the blower:
1. Forced air creates flying debris. Always wear personal protective
equipment. Severe personal injury could result.
2. Ensure no personnel are in the destination access vault during the
blowing operation. Severe personal injury could result.
2.