beautypg.com

Program example 1 – Carbolite 3508 User Manual

Page 15

background image

Notes

15

MC19-1.20

5.13 Program Example 1

The following sequence of entries creates and runs the program shown graphically below.

1.

Turn the controller SP down to ‘0’ by pressing down

.

2.

Press page

 until Prog, Segments Used is displayed. On P10 or P25 models press

up

 or down  to select a new program number, (a program with only 1 segment).

3.

Press scroll

 until Holdback Value is displayed. Default ‘0’ degrees.

4.

Press scroll

 until Ramp Units is displayed. Press up  or down to set to ‘Min’

5.

Press scroll

 until Cycles is displayed. Default ‘1’

6.

Press scroll

 until Segment 1 is displayed

7.

Press scroll

 until Segment Type is displayed. Press up  or down to select

‘Rate’

8.

Press scroll

 until Holdback Type is displayed. Default ‘Off’

9.

Press scroll

 until Target SP is displayed. Press up  or down to set to ‘400’

degrees.

10.

Press scroll

 until Ramp Rate is displayed. Press up  or down to set to ‘5.0’

degrees per minute.

Repeat steps 6 to 10 for 4 more segments. Set Holdback to the default ‘Off’. Enter the
following parameters and values:

Segment Typ

e Dwell Duration ‘30:00.0’ minutes

Segment Type Step Target SP ‘600’ degrees
Segment Type Dwell Duration ‘30:00.0’ minutes
Segment Type Time Target SP ‘200’ degrees, Duration ‘2:00:0’ hours

Finish the program with an End segment:

11.

Press scroll

 until Segment Type is displayed. Press up  or down to select

‘End’
12.

Press scroll

 until End Type is displayed. Press up  or down to select ‘Reset’

13.

Press page

 and scroll  together to return to the home display.

To run the program either press RUN/HOLD or:

14.

Press page

 until Program Status is displayed

15.

Press scroll

 until the cursor moves to the program status of ‘Reset’

16.

Press

 to select ‘Run’.




Segment 1
Type ‘Rate’
Target 400°
Rate 5.0°/Min

Segment 2
Type ‘Dwell’
Duration
30min

Segment 3
Type ‘Step’
Target 600°

Segment 4
Type ‘Dwell’
Duration
30min

Segment 5
Type ‘Time’
Target 200°
Time 2 hours

Segment 6
Type ‘End’
End type
‘Reset’

400°C

600°C

200°C

5°C/m

30min

30min

2 hours

Time display examples

10:05.3 Min / Sec / 10

th

Sec

24:10:05 Hour / Min / Sec
196:10 Hour / Min