background image

ADDITIONAL BREAKER

REQUIRED IF GREATER

THAN 10 FEET

CONNECT

TO AC HOT

LOAD(S)

NEUTRAL

PIGTAIL

LINE

1

LOAD

1

N

N

SENSOR COIL

TO AC SAFETY GROUND SOURCE

DC BACKLIGHT

BOARD

FROM DEVICE

SAFETY

GROUND

FROM DEVICE

NEUTRAL

FUSE 1.0 TO 2.0A

AC SAFETY

GROUND BUS

AC NEUTRAL

BUS

R.P.

LED

LED

FROM AC HOT SOURCE

FROM AC NEUTRAL SOURCE

SHORE

POWER

INLET

Installation

(continued)

4. Install feed circuit wires

Install the feed wires from the shore power inlet or other AC source,

referring to the wire sizing chart to select the correct wire size. Connect

the black AC hot, white AC neutral and green AC safety ground as

shown in the illustration.

If the feed wires are from the shore power inlet or the electrical

attachment point of a permanently installed shore power cord and the

inlet or attachment point is more than 10 feet from this panel, additional

fuses or circuit breakers must be installed within 10 feet of the shore

power inlet. The measurement is made along the conductors.

5. Installation of Backlight System

The backlight board is a DC device. When installing it in an AC panel

both wire leads must be connected to an appropriate DC source

and ground.

Connect the yellow negative wire to a DC ground. Connect the red

positive wire to a DC positive supply, usually a switch that controls

the vessel’s other nighttime illumination.

6. Apply branch circuit labels and mount panel

Apply a label for each circuit from the label set provided. Extended

label sets are available through retail suppliers, and over 500 individual

labels are available directly from Blue Sea Systems. Please go to

www.bluesea.com to order individual labels for specific applications.

Fasten the panel to the mounting surface using the screws provided.

7. Testing

Connect the vessel’s shore power and verify the Reverse Polarity

light is not illuminated. If the red Reverse Polarity light is on then

either the hot and ground or the hot and neutral wires have been

crossed. Starting at the panel, trace the connections back as far as

necessary to locate the error.

Using a multimeter where the power source is connected to the

panel verify:

a. 120 volts between hot and neutral

(nominal, this may vary depending on source voltage)

b. 120 volts between hot and ground.

c. 0 volts between neutral and ground.

Turn on each branch circuit to verify power to each circuit.

Refer to Carling Technologies™ PB-Series ELCI/RCBO installation

Bulletin for Marine Main Circuit Protection, (IST-0006), for test

procedure and frequency.

8. Optional Branch LEDs

This Panel is supplied with LEDs pre-installed in all optional branch

positions. For future expansion of the panel remove the hot leg of the

LED from the AC Neutral Bus and connect it to the Load side of the

branch circuit breaker.

Note

Blue Sea Systems’ 8101 and 8102 electrical distribution panels

are furnished with two 15A AC branch circuits. This rating will satisfy

the vast majority of marine circuit protection situations.

Related Products from Blue Sea Systems

• 360 Panel System

• Battery management solutions

• AC and DC circuit protection devices

• WeatherDeck waterproof circuit breaker panels

• Fuses, fuse blocks, and BusBars

• Analog and digital meters

Useful Reference Books

• Calder, Nigel (2005). Boatowner’s Mechanical and Electrical Manual

(3d ed). Camden ME: International Marine / McGraw-Hill.

• Wing, Charlie (2206). Boatowner’s Illustrated Electrical Handbook

(2d ed). Camden ME: International Marine / McGraw-Hill.

Keep all supplied instructions with boat system records

for future reference.

ADDITIONAL BREAKER

REQUIRED IF GREATER

THAN 10 FEET

LINE

1

LOAD

1

N

N

SENSOR COIL

TO AC SAFETY GROUND SOURCE

DC

BACKLIGHT

BOARD

FROM

DEVICE

SAFETY

GROUND

FROM

DEVICE

SAFETY

GROUND

FROM

DEVICE

NEUTRAL

R.P.

LED

LED

LED

LED

LED

LED

LED

AC SAFETY GROUND BU

S

AC NEUTRAL BU

S

FROM AC HOT SOURCE

FROM AC NEUTRAL SOURCE

SHORE

POWER

INLET

NEUTRAL

PIGTAIL

TO DC

NEGATIVE

FROM DC

POSITIVE

TO DEVICE

HOT

TO DEVICE

HOT

15A

15A

BRANCH

CIRCUIT

R.P.

LED

FUSE

DC

BACKLIGHT

BOARD

1.0 TO 2.0A

AC

VOLTMETER

+12V
+24V

-Neg

Red

Orange

Yellow

LED

LED

LED

LINE

1

LOAD

1

N

N

AC NEUTRAL BU

S

FROM

DEVICE

NEUTRAL

SENSOR COIL

TO AC SAFETY GROUND SOURCE

FROM AC HOT SOURCE

FROM AC NEUTRAL SOURCE

SHORE

POWER

INLET

ADDITIONAL BREAKER

REQUIRED IF GREATER

THAN 10 FEET

NEUTRAL

PIGTAIL

FROM

DEVICE

SAFETY

GROUND

AC SAFETY GROUND BU

S

Wiring Diagram PN 8102 - 120V AC ELCI Panel, 30A Main, 2 Position, Voltmeter

Wiring Diagram PN 8101 - 120V AC ELCI Panel, 30A Main, 5 Position

Wiring Diagram PN 8100 - 120V AC ELCI Panel, 30A Main