Panel Specifi cations

Material:

0.125” 5052-H32 Aluminum Alloy

Primary Finish:

Chemical Treatment per Mil Spec C-5541

Final Panel Finish:

Graphite color 2 part textured Polyurethane

Circuit Breakers:

Double Pole Carlingswitch B Series AC / DC

Magnetic Breakers 65VDC/277VAC Maximum

Amperage Rating: PN 8132 / 3132 is rated for 16 amp service

PN 8161 / 3161 is rated for 32 amp service

Voltage Rating:

Panel is rated for 230 volts AC and is so marked in
order to comply with ABYC standards

Inches

Millimeters

Overall Dimensions: 5-1/4 x 3-3/4

133.40 x 95.30

Mounting Centers:

4-7/16 x 2-15/16

112.70 x 74.60

Standards:

This panel, when properly installed, complies with
all applicable Standards and Recommended
Practices of the American Boat and Yacht Council
as well as United States Coast Guard 33 CFR Sub
Part 1.

The Purpose of the AC Main Source Selector Panel

Alternating Current (AC) power changes polarity 60 times per second in
the US, Canada and Latin America and 50 times per second in Europe.
This is the frequency of the power and is referred to as Hertz (or the now
outdated term “cycle”). Because of this alternating nature of AC power,
two live sources of AC power, such as shore power and inverter power,
or shore power and a generator, cannot be electrically connected. The
AC Main Source Selector panel is designed to connect two sources of
AC power to a common circuit while preventing both sources from being
connected to the circuit simultaneously.

Blue Sea Systems Inc.

Phone (360) 738-8230

425 Sequoia Drive

Fax (360) 734-4195

Bellingham, WA 98226 USA

E-mail [email protected]

www.bluesea.com

Document 9811 Rev.I

WARNING

@

It is not possible within the scope of these instructions to fully acquaint

the installer with all the knowledge of electrical systems that may be

necessary to correctly install this product. If the installer is not

knowledgeable in electrical systems we strongly recommend that an

electrical professional be retained to make the installation.

@

If either the panel front or back is to be exposed to water it must be

protected with a waterproof shield.

@

The panels must not be installed in explosive environments such as

gasoline engine rooms or battery compartments as the circuit breakers

are not ignition proof.

@

The vessel’s shore power cord must be disconnected form shoreside

power before installing this electrical panel.

@

If an inverter is installed on the vessel its power leads must be

disconnected at the battery before the panel installation. Be aware that

many inverters have a “sleep mode” in which their voltage potential

may not be detectable with measuring equipment.

@

If an AC Generator is installed aboard it must be stopped and rendered

inoperable before the panel is installed.

@

Verify that no other AC source is connected to the vessel’s wiring

before the panel is installed.

Guarantee

Any Blue Sea Systems product with which a customer is not satisfi ed
may be returned for a refund or replacement at any time.

Installation

1. Disconnect all AC and DC power

Disconnect all AC power originating on or off the vessel. This includes

inverters, generators, shore power attachments and any other device

capable of supplying AC power to the ship’s circuits.

Disconnect the main positive DC cable from all batteries to eliminate

the possibility of a short circuit and to disable the inverter while

installing the distribution panel.

2. Select mounting location and cut opening

If this panel is to serve as your main shore power disconnect circuit

breaker, select a location which is not more then 10 feet from the shore

power inlet or the electrical attachment point of a permanently installed

shore power cord as measured along the conductors of the feed wires.

If it is more then 10 feet, additional fuses or circuit breakers must be

installed within 10 feet of the shore power inlet.

Select a mounting location which is protected from water on the panel

front and back and is not in an area where fl ammable vapors from

propane, gas or lead acid batteries accumulate. The circuit breakers

used in marine electrical panels are not ignition protected and may

ignite such vapors.

Using the panel template provided, make a cut out in the mounting

surface where the distribution panel is to be mounted. Do not yet

fasten the panel to the mounting surface.

3. Install source 1, source 2 and output wires

Install the feed wires from AC source 1 and AC source 2. Install the

output wires. Refer to the wire sizing chart to select the correct wire

size. Connect the black AC hot, white AC neutral and green AC safety

ground as shown in the illustration.

AC Main Source Selector Panels

PN 8132 / PN 3132 / PN 8161 / PN 3161

Do not confuse the neutral current carrying wires (sometimes called
ground) with the green normally non-current carrying wires (sometimes
called grounding). These two wires must be connected only at the
source of power, nowhere else.

If the feed wires are from the shore power inlet or the electrical
attachment point of a permanently installed shore power cord and the
inlet or attachment point is more then 10 feet from this panel, additional
fuses or circuit breakers must be installed within 10 feet of the shore
power inlet. The measurement is made along the conductors.

Wire sizing chart

Use the wire sizing chart below to determine the proper branch and

feed circuit wire sizes.

Note:

This chart assumes wire with 105° C insulation rating

and no more than 2 conductors are bundled.

Not suitable for sizing flexible shore power cords.