beautypg.com

Service (cont.) – Bunn POWDER AUTO FILL User Manual

Page 24

background image

24

SERVICE (cont.)

LAMP CORD CONNECTOR

If continuity is present as described, the lamp cord
connector is operating properly.

If continuity is not present as described, replace the
lamp cord connector.

Removal and Replacement:
1. Disconnect the lamp cord assembly from the lamp

cord connector.

2. Remove the six #8-32 screws securing the rear

cover to the dispenser.

3. Disconnect the lamp cord connector wires from

the dispenser main wiring harness.

4. Remove nut and washer securing the lamp cord

connector to the dispenser. Remove and set aside
the insulating washers and discard nut, washer
and lamp cord connector.

5. Remove new nut and washer from new lamp cord

connector.

6. Install the insulating washers to the hole in the top

of the dispenser. Push new lamp cord connector
through the holes in the insulating washers and
secure with the new nut and washer.

7. Reconnect the wires on the cord connector to the

dispenser main wiring harness.

8. Connect the lamp cord to the lamp cord connector.
9. Install the rear cover to the dispenser and secure

with six #8-32 screws.

FIG. 20 LAMP CORD CONNECTOR

P1928

FIG. 19 LAMP CORD CONNECTOR

P1923

Location:

The lamp cord connector is located on top of the

dispenser.

Test Procedures:
1. Disconnect the dispenser from the power source.
2. Disconnect the lamp cord from the lamp cord

connector.

3. Disconnect the plug on the dispenser main harness

from the connector from the lamp cord connector.

4. Check the voltage across the two pin holes on the

main harness plug with a voltmeter and Day/Night
switch in the "DAY" position and the "ON/OFF"
switch in the "ON" position. Verify that the dispenser
hopper is full and in place, the dispenser probe
contact is making contact with the CDS liquid level
probe, and the dispenser door is closed. Connect
the dispenser to the power source. The indication
must be approximately 12.6 volts ac.

5. Disconnect the dispenser from the power source.

If voltage is present as described, proceed to #6.

If voltage is not present as described, refer to the wir-
ing diagram and check the dispenser main wiring har-
ness.
6. Check for continuity between pin 1 (red) of the lamp

cord connector and the center terminal of the lamp
cord connector. Check for continuity between pin 2
(black) of the lamp cord connector plug and the
lamp cord connector body. Check for continuity
between pins 1 & 2 of the lamp cord connector plug.
Continuity must not be present between pins 1 & 2.

To Main Harness

29793 061599