TROUBLESHOOTING (cont.)

PROBABLE CAUSE

REMEDY

PROBLEM

Powder Auto-Fill will not dispense
product

Dripping from dispense tip

Water flows continuously

1. No water

2. No power or incorrect voltage to
the dispenser.

3. Dispense Solenoid Valve

4. Control Board and Probe

5. Auger Drive

6. Transformer

7. Water Strainer (Optional)

1. Dispense Solenoid Valve

1. Control Board and Probe

2. Dispense Solenoid Valve

Water lines and valves to the dis-
penser must be open and free of
obstructions.

Check that the power cord is con-
nected to the CDS dispenser and for
voltage from the CDS dispenser.

Refer to Service- Dispense Solenoid
Valve for testing procedures. See
page 32

Refer to Service- Control Board and
Probe for testing procedures. See
page 18

Refer to Service- Auger Drive for
testing procedures. See page 13

Refer to Service- Transformer for
testing procedures. See page 26

A) Direction of flow arrow must be
pointing towards dispenser.

B) Remove the strainer and check
for obstructions. Clear or replace.

Remove dispense valve and clear
any obstructions. Rebuild or replace
the valve if necessary. Seepage 32

Refer to Service- Control Board and
Probe for testing procedures. See
page 18

Refer to Service- Dispense Solenoid
Valve for testing procedures. See
page 32