beautypg.com

General maintenance – Autoquip CMD DOCK LIFT User Manual

Page 24

background image

24

WIRING THE MOTOR

Use the following chart in connecting these motors to power sources.

HP and Source

AMP Draw

(full load)

2 HP / 115 V/60 CY/1 PH

22 A

2 HP / 230 V/60 CY/1 PH

11 A

NOTE: 115V/1ph/60Hz operation is not recommended. If 115V/1ph operation is
absolutely required, the lift will function properly if adequate power is supplied.
However, it is very sensitive to deviations from the required power. Consequently,
performance could prove unsatisfactory. To assure proper operation on 115V/1ph/60Hz
power supply, a separate circuit, protected by a 30 AMP time delay circuit breaker, and
adequate wiring should be provided to allow and actual 115V at the power cord plug
during fully loaded operation. Specify if required.

MOTOR CONNECTION DIAGRAMS

GENERAL MAINTENANCE