Operating instructions – Autoquip GATES VERTICAL ACTING User Manual
Page 38

38
 
 
OPERATING INSTRUCTIONS
POWERED GATES
DANGER
!
To avoid personal injury or death, do not operate this 
equipment with substandard, defective, or missing parts. 
Contact a local Autoquip service representative if a 
deficiency is found. 
WARNING
!
Never run the unit with the gates or doors open! The gates 
must not open when the lift is in operation or when the platform 
is not present. Should this condition exist, the interlock is not 
functioning properly due to incorrect installation or damage. 
This condition must be corrected immediately. Failure to 
correct this condition may result in serious injury or death. 
 
Powered vertical gates are electromechanically driven in both directions using 
UP/DOWN operator controls. 
 
UP
 
When the UP button is pressed or drop cord pulled, the brake motor is started and the 
gearbox output shaft rotates the chain sprockets. The gate chains go over these 
sprockets and then attach to counter weights. As the motor rotates, the output shaft 
turns and raises the gate, provided the motor rotation is correct. If the gate does not 
move, check the motor rotation and correct if necessary. 
 
The gate will continue to move upward as long as the button or cord is held. When the 
gate panel reaches the upper travel limit switch, the motor will stop and the motor brake 
will be applied. 
 
 
 
 
 
 
