6 - shade selection guide, Filter specifications – ArcOne Carrera, Europe User Manual
Page 7
![background image](/manuals/554858/7/background.png)
- 6 -
Shade Selection Guide
CE Shade selection Guide (Table 2)
Current
(Amps)
Process
1.5
6
10
15
30
40
60
70
100 125 150 175 200 225 250 300 350 400 450 500 600
Covered Electrodes
8
9
10
11
12
13
14
MAG
8
9
10
11
12
13
14
TIG
8
9
10
11
12
13
MIG with heavy metals
9
10
11
12
13
14
MIG with light metals
10
11
12
13
14
Air-arc gouging
10
11
12
13
14
15
Plasma jet cutting
9
10
11
12
13
Micro-plasma arc welding
4
5
6
7
8
9
10
11
12
1.5
6
10
15
30
40
60
70
100 125 150 175 200 225 250 300 350 400 450 500 600
NOTE: The term "heavy metals" applies to steels, alloy steels, copper and its alloys, etc.
***From CE EN 169:2002
2000T
1000FcF
2000V
Viewing Area
3290 mm
2
3290 mm
2
4704 mm
2
Filter Size (mm)
90x110
90 X 110
90 X 110
ARC Sensing
Two sensors
Two sensors
Two sensors
Sensitivity Control
Fixed
Variable
Variable
Switching Time
(seconds)
5/10,000
(0.5 milliseconds)
1/10,000
(0.1 milliseconds)
5/10,000
(0.5 milliseconds)
Primary Power
Solar Cells
Solar Cells
Solar Cells
Back-up Power
Lithium Battery
Lithium Battery
Lithium Battery
Operating & Storage
Temperature
14 – 131F
(-10 – 55C)
14 – 131F
(-10 – 55C)
14 – 131F
(-10 – 55C)
UV / IR Protection
Up to Shade 16
Up to Shade 16
Up to Shade 16
Dark to Light Delay
0.1 seconds
0.1 & 2 seconds
0 - 2 seconds
Light Shade
3
4
4
Dark Shade
11
9-13
9-13
Grind Mode
No
Yes
No
Enclosure
Integrity
Not Dust / Water
Resistant
Not Dust / Water
Resistant
Dust / Water
Resistant
Standards
CE EN379
*CE EN379
***CE EN379
Optical Class
1
1
1
Diffusion of Light Class
2
3
3
Variation in Luminous
Transmittance Class
1
1
1
Angle Dependency Class
N/A
N/A
3
Filter Specifications
(Table 1)
*Certottica certified