Relay jumper settings, 3 = n o 1 -2 = n c – APG DCR-WEB user manual User Manual

Page 8

background image

DCR-WEB

Rev. A3, 10/08

8

Automation Products Group, Inc.

APG...Providing tailored solutions for measurement applications

Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]

R

E

L

A

Y

R

E

L

A

Y

2

-3

=

N

O

1

-2

=

N

C

Relay Jumper Settings

Default = NO

1

3

3
2
1

2

• Wiring

Step 1: Mount sensor so that transducer has a clear path to the target.

Step 2: To obtain access to the terminal strip, remove the front cover by

turning out the 4 screws. This will expose the terminal strip and 2 X 8 character
display.

Step 3: Wires can be pulled into the DCR-WEB through the strain reliefs on

the enclosure.

The screw terminal can be wired using solid or stranded wire between 16 - 20

AWG. Wires should be stripped, leaving a 0.4 in. bare wire.

Follow the legend on the circuit board when wiring. The DCR-WEB should

never be used without the earth ground terminal being connected.

Step 4: Perform an internal check to ensure that all wires are properly

connected and secured.