Bryant 556A User Manual

Page 2

background image

ACCESS

PANEL

1

1

/

4

"

1.

Allow 30 in.

clearance to service end of unit, 48 in. above unit, 6 in. on one side, 12 in. on remaining side,

and 24 in. between units for proper airflow.

Minimum outdoor operating ambient in cooling mode is 55

°

F (unless low-ambient control is used) max 125

°

F.

2.

Series designation is the 14th position of the unit model number.

3.

Center of gravity .

4.

NOTES:

AIR DISCHARGE

AIR DISCHARGE

AIR IN

AIR IN

AIR IN

2

1

/

2

"

AIR DISCHARGE

1

3

/

4

"

4

3

/

16

"

3

/8-IN.

DIA LIQUID

LINE CONN

H

DIA VAPOR

LINE CONN

8

3

/

16

"

7

/8-IN.

DIA HOLE

FIELD POWER SUPPLY CONN

7

/

8

-IN.

DIA

HOLE WITH 1

1

/

8

-IN.

DIA KNOCKOUT (ALL SIZES)

AND 1

3

/

8

-IN.

DIA KNOCKOUT

(042 THRU 060 SIZES ONLY)

3

/

8

-IN.

DIA TIEDOWN KNOCKOUTS

(2) PLACES IN BASEPAN

10

1

/

2

"

FIELD CONTROL

SUPPLY CONN

1

9

/

16

"

L

C

F

N

G

A

B

M

K

E

D

C L

A97001

DIMENSIONS

(IN.)

UNIT

SIZE

SERIES

UNIT

DIMENSIONS

MINIMUM

MOUNTING

PAD

DIMENSIONS

AB

C

D

E

F

G

H

K

L

M

N

024

A

39-13/16

30

33

5-1/16

9-11/16

27-15/16

34-3/8

5/8

TBD

TBD

TBD

2-15/16

26

X

3

2

030

A

39-13/16

30

33

5-1/16

9-11/16

27-15/16

34-3/8

3/4

TBD

TBD

TBD

2-15/16

26

X

3

2

036

A

39-13/16

30

33

5-1/16

9-11/16

27-15/16

34-3/8

3/4

TBD

TBD

TBD

2-15/16

26

X

3

2

042

A

39-13/16

30

33

5-1/16

9-11/16

27-15/16

34-3/8

7/8

TBD

TBD

TBD

2-15/16

26

X

3

2

TBD—To

Be

Determined

—2—