Audio monitor, Signal generator, Factory reset unit settings – Allen&Heath iDR-4 User Manual
Page 46: Factory reset configuration settings, Factory reset patch parameters

46
IDR-4 User Guide
Audio Monitor
Stereo audio monitor with line output
Configurable from line in/out 5 and 6
Ripple through capability for linked units
Select source manually or follow mouse movements
Display – stereo meters
Controls – fader, mute
Signal Generator
Source variable frequency sine wave, white noise,
pink noise, band pass pink noise
Sine wave / band pass range 20Hz to 20kHz
Controls – fader, mute
Factory RESET unit settings
Unit name – iDR Unit Name
Network settings
DHCP
–
No
IP address – 192.168.0.1
Net mask – 255.255.255.0
Gateway
address
PPP settings
Host IP address – 192.168.0.1
Client IP address – 192.168.0.2
User name – iDR
Password
–
A&H
Factory RESET configuration settings
Input channel names
I/P 1…. I/P 16
Output channel names
O/P 1…. O/P 16
Input group names
IP Grp 1…. IP Grp 8
Output group names
OP Grp 1…. OP Grp 8
Stereo selections
All
mono
Communications option
A RS232 B SysNet
Scheduled events
None
Power-up patch
None
All patches empty
Factory RESET patch parameters
AMM
No active inputs or outputs
Threshold
7dB
Gate depth 40dB
Hold time 1s
NOM
attenuation
3dB
Output delays
All
0ms
Input faders, mutes, groups
Fader levels and mutes off
Group
assignments
none
Group levels 0dB
Input patchbay
Physical input 1 to Channel 1….
Physical input 6 to Channel 6
Expander 9 to Channel 9….
Expander 16 to Channel 16
Output patchbay
Channel 1 to physical output 1….
Channel 6 to physical output 6
Expander 9 to XLR 9….
Expander 16 to XLR 16
LCD
Line 1 – user text ‘Allen & Heath’
Line
2
–
time
Mic preamps
Pad
on
Gain +20dB (resulting gain 0dB)
+20V
off
Line preamps
Gain
0dB
Monitor manager
Monitor disabled (Independent Outputs)
Routing matrix
All cross points 0dB (on)
Signal generator
Signal type – sine wave
Frequency
–
440Hz
Level - -30dB
Front panel soft keys
S1-S4 – input level control CH1-4
S5-S8 – output level control CH1-4
iDR-switch inputs
S1-S24
–
unused
Front panel soft LEDs
L1-L8 – static LED off
L9-L12 – input source meters CH1-4
L13-L16 – output post limiter meters CH1-4
iDR-switch outputs
S1-S16 – static LED off
Input expander
S1-S8 – input source meters CH9-16
Output expander
S1-S8 – Output post limiter meters CH9-16