Specification – Allen&Heath GR2 PL-12 USER GUIDE 1 User Manual
Page 20

20
GR2 User Guide
Specification
System
Output
level
control
VCA
signal
path
Front panel or remote DC control
Paging
Configured independently to zone 1 and 2
Triggered
by
page
mix
signal
presence
Threshold -20dB
Ducking
depth
-20dB
Music 1 priority
Configured independently to zone 1 and 2
Triggered
by
music
1
signal
presence
Threshold -20dBu
Release time selectable short = 2 seconds, long = 12 seconds
Routing
Zone 1 = music only, or music+mic mix
Zone 2 = nothing (page only), music, mic mix, or music+mic mix
Aux = any combination of page mix, mic mix, zone 1 or zone 2 mix
Signal meters
2-colour LED for each input and output
Green = signal –12dB, red = peak +15dB (5dB before clipping)
Page mix equaliser
Fixed HPF 150Hz, LPF 8kHz
Mic mix equaliser
HPF swept frequency 20 to 400Hz
MF
±
12dB swept frequency 180Hz to 5kHz
HF
±
10dB shelving 12kHz
Zone 1 equaliser
LF
±
12dB 80Hz shelf, HF
±
12dB 10kHz shelf
Inputs
Mic/line 1-6 in
Balanced Phoenix screw terminal (mic 1 duplicated on XLR, pin2 hot)
Pad out
2k ohm -60 to -20dBu
Pad in
10k ohm -30 to +20dBu
Phantom power = +15V
Stereo music 1,2,3 in
Dual RCA phono 50k ohm
-10dBV or +4dBu
Mix expander in
Balanced Phoenix screw terminal 10k ohm 0dBu
Page in
Balanced Phoenix screw terminal 10k ohm 0dBu
Outputs
Zone out 1,2 out
Impedance balanced Phoenix screw terminal (Duplicated on RCA phono)
0dBu
<75ohm
Aux out
Impedance balanced Phoenix screw terminal (Duplicated on RCA phono)
0dBu <75ohm
Performance
Maximum output
+20dBu into 2k ohm
Internal headroom
+20dB
Frequency response
20Hz to 20kHz +0/-1dB
Noise
Residual output noise (zone level min) <-91dBu
Mix noise (one selection, (zone level max) < -85dBu
Power supply
Mains Power Input
3pin IEC male socket
Universal mains input 100-240V.AC 47-63Hz 25VA max
Supplied with country dependent mains power lead
Fuse
T1AL
250V
20mm