Remote control – pl-12 wall plate, Gr2 user guide, Control – Allen&Heath GR2 PL-12 USER GUIDE 1 User Manual
Page 15: Cat5 cables, Zone selection, Setup menu options, Wired switch options, Pl-5 infra-red controller, Working with presets, Pl-12 setup options

GR2 User Guide
15
WARNING
THIS APPARATUS MUST BE EARTHED.
GR2
ZONE OUT
AUX
Z1
Z2
OUT
L
R
MUSIC IN
1
2
3
L
R
L
R
L
R
-
G +
Z1L
MIC 1
G
-
+
Z1R
-
G +
Z2
G
-
+
AUX
-
G +
MIC 3
G
-
+
MIC 4
-
G +
MIC 1
G
-
+
MIC 2
-
G +
MIC 5
G
-
+
MIC 6
-
G +
PAGE
G
-
+
MIC MIX
ZONE REMOTE
UTILITY REMOTE
EXPAND IN
( R - MUSIC 4 - L )
MADE IN THE UK BY ALLEN & HEATH LIMITED
ATTENTION: REMPLACER PAR UN FUSIBLE STRICTEMENT IDENTIQUE EN VALEURS.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
REPLACE FUSE WITH SAME TYPE AND RATING.
ALLEN&HEATH
WARNING
THIS APPARATUS MUST BE EARTHED.
GR2
ZONE OUT
AUX
Z1
Z2
OUT
L
R
MUSIC IN
1
2
3
L
R
L
R
L
R
-
G +
Z1L
MIC 1
G
-
+
Z1R
-
G +
Z2
G
-
+
AUX
-
G +
MIC 3
G
-
+
MIC 4
-
G +
MIC 1
G
-
+
MIC 2
-
G +
MIC 5
G
-
+
MIC 6
-
G +
PAGE
G
-
+
MIC MIX
EXPAND IN
( R - MUSIC 4 - L )
MADE IN THE UK BY ALLEN & HEATH LIMITED
ATTENTION: REMPLACER PAR UN FUSIBLE STRICTEMENT IDENTIQUE EN VALEURS.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
REPLACE FUSE WITH SAME TYPE AND RATING.
ALLEN&HEATH
SOURCE
INDICATOR
LEVEL
LEVEL
INDICATOR
CONTROL
INFRA-RED
SENSOR
5
4
3
2
1
LEVEL
UP/DOWN
SOURCE
SELECT
SOURCE SELECT
MUSIC
MUTE
SOURCE OFF
PRESETS
5
4
3
2
1
PL-5
5
4
3
2
1
6
7
8
9
12
13
10
11
14
PL-12 WALL PLATE
PL-5 IR CONTROLLER
WALL PLATE DISABLE
Z2
Z1
Z2
Z1
WIRING OPTIONS
Z2 FOLLOW Z1
(ROOM COMBINING)
CAT5 CABLE
CAT5 CABLE
ITEM
SETUP
ITEM
SELECT
SETUP
OPTIONS
ENTER
SETUP
SOURCE
SELECT
SETUP MENU
FUSE: T1AL
100 - 240V~
47-63Hz ~ 25W MAX
Remote Control – PL-12 Wall Plate
The optional Allen & Heath PL-12 ‘intelligent’ wall plate provides
remote control of zone source selection and level. Full setup and
operating instructions are detailed in the PL-12 user guide. The
following provides an overview of its capability.
Control
A rotary level control provides 32 steps from fully off to
fully on. Up/down keys toggle through the available sources with
LEDs to indicate which source is active. An infra-red detector senses
the optional PL-5 hand held remote if it is used.
CAT5 cables
A standard CAT5/RJ45 cable connects between the
ZONE REMOTE port and the first PL-12 wall plate. Another cable
connects from the first wall plate to a second if both zones require
remote control. The control for both zones is passed down a single
CAT5 cable. This can be convenient for cable installation and for
situations where one remote is used to control both zones.
Zone selection
A jumper plug on the wall plate circuit card sets
which zone to control. Each zone can be controlled by one plate
only. However, you can set one plate to control both zones.
Setup menu options
The PL-12 presents the installer with many
setup options to satisfy the custom requirements of the application,
shown in the table here. These are accessed using setup mode.
Wired switch options
Two switch options are available at the
PL-12 wall plate. One switches operating mode for zone 2 control to
follow zone 1, convenient for room combining situations where a
divider screen is fitted with a switch to toggle mode. This switch
should be wired to the first wall plate. Another set of contacts can be
wired to a remote switch to disable the wall plate when it should not
be used by the operator.
PL-5 infra-red controller
The optional hand held controller may
be used with the IR detector on the PL-12 wall plate for wireless zone
level control and source selection. It provides additional functions
including direct source selection, a source mute switch and a preset
store/recall system.
Working with presets
The PL-5 hand held controller allows the
storing and recall of up to 4 presets of level, source selection and
zone 2 follow 1 setting. The installer can store these during
installation, then disable store to prevent them being overwritten by
the operator.
PL-12 setup options:
Zone 2 follow zone 1 = on, off
One PL-12 controls both zones
Sources to select = 1234, 123, 234, 23
Choose which sources can be selected
Source off = enabled, disabled
Allow a source off position
Power up = last settings, off, preset
Default settings when power is applied
Power up preset = 1, 2, 3, 4
Which preset to select if enabled above
Preset recall = enabled, disabled
Allows recall of presets using the PL-5
Preset store = enabled, disabled
Allows saving of presets using the PL-5
Follow mode = source only, source+level
What to control when in zone 2 follow zone 1
mode.
The PL-12 can be reset to factory default
(settings shown in bold above).