Appendix A: Alarm I/O Connector
Some features of the Camera can be activated by the external sensor that senses physical
changes in the area Camera is monitoring. These changes can include intrusion detection
or certain physical change in the monitored area. For examples, the external sensor can be
a door switch or an infrared motion detector. These devices are customer provided, and are
available from dealers who carry surveillance and security products. Electrically, they must
be able to provide a momentary contact closure.
This Camera provides wires for general I/O terminal and RS485 interface as below:
Cable for I/O connectors:
Name Cable
Color
Function
12VDC
Brown/White
DC 12V (50mA maximum)
GND Blue/White GND
D+ Purple/White
RS485
data
+
D- Gray
RS485
data
-
DI
Green/White
Digital signal input
DO
Orange/White
Digital signal output
User can refer to the schematic below to make a proper connection between I/O connector
and external sensor and output device.
Explanation of External I/O Circuit Diagram: