beautypg.com

4 flash codes for the control light – Echo CH611DH Owners Manual v.2 User Manual

Page 30

background image

26

6 INCH CHIPPER

SPECIFICATIONS

CoNTRoLLER FLaSH CoDES GuIDE

SIGNaL

FREQuENCY

CauSE

aCTIoN To TaKE

Green

Solid

Forward feed available.

Begin feeding materials into the

chute.

Green

One flash per second

RPM not high enough to chip upon

initial startup.

Increase RPM until the green light

stops flashing.

RPM dropped suddenly while chipping

due to an obstruction.

No action necessary, the feed

roller will automatically reverse to

clear the obstruction.

Red

One flash per second

Feed bar is not in STOP (upon initial

startup or when RPM has dropped).

Put feed bar in STOP position.

Red

Solid

(CE compliant models only). light is

solid red upon startup.

Push reset/override button to

reset.

(CE compliant models only). Safety bar

was activated.

(NON-CE compliant models only).

Jumper harness plug was damaged.

Check connections to jumper

harness plug. Replace if plug

necessary (PN 36391-00)

Amber

long and short flashes at

initial startup

When the controller is started up, it

will flash an amber code to show total

hours of operation. Each long flash

equals 10 hours of operation, each

short flash equals 1 hour of operation.

No action necessary. The hours of

operation code can be interrupted

by engaging the feed roller.

Amber

Two flashes followed by a 1.5

second pause and then two

flashes followed by a long

pause

Chipper blades should be checked and

sharpened if necessary.

Check sharpness of chipper

blades. Check sharpness of

chipper blades. Reset the

controller by setting the feed bar
in the StoP position.

Without

starting the machine

, turn the

key to the ON position. With the

key remaining in the ON position,

shift the feed bar from one of the

REVERSE positions to the other

REVERSE position and back,

three times within eight seconds.

Amber

Three flashes followed by a

1.5 second pause and then

three flashes followed by a

long pause

Engine oil should be changed.

Change oil. Reset the controller by

setting the feed bar in the STOP

position. Without starting the

machine, turn the key to the ON

position and WAIT 10 SECONDS.

With the key remaining in the ON

position, shift the feed bar from

one of the REVERSE positions

to the other REVERSE position

and back, three times within eight

seconds.

Amber

Two flashes followed by a 1.5

second pause and then five

flashes followed by a long

pause

Forward feed has a short or open

circuit.

Check connections to the forward

coil on the feed hydraulic valve.

Replace coil if necessary.

Amber

Two flashes followed by a

1.5 second pause and then

six flashes followed by a long

pause

Reverse feed has a short or open

circuit.

Check connections to the reverse

coil on the feed hydraulic valve.

Replace coil if necessary.

7.4 FLaSH CoDES FoR THE CoNTRoL LIGHT