beautypg.com

8 replacing hydraulic drive belt, 9 fill coolant (diesel), 10 change oil – Echo CH611DH Owners Manual v.2 User Manual

Page 23: English

background image

19

6 INCH CHIPPER

ENGLISH

SERVICE & MAINTENANCE

BEFORE INSPECTINg OR SERVICINg ANy PART OF THIS MACHINE, SHuT OFF POWER SOuRCE,

DISENgAgE THE HyDRAulICS, AND MAKE SuRE All MOVINg PARTS HAVE COME TO A COMPlETE STOP.

WaRNING

5.8 REpLaCING HYDRauLIC DRIvE bELT

Remove drive belt according to instructions in Section

1.

5.5.
loosen the two bolts under the pump. Access is from

2.

underneath chipper (see figure below).
Slide the pump up, remove the loosened hydraulic

3.

belt and discard.
Install the new hydraulic belt.

4.

Replace the drive belt according to directions in Section

5.

5.5.
Tighten the nuts on the adjusting bolt to move the pump

6.

mounting bracket. Stop when the belt deflection at the

center of the belt is 7/16" when a 20 lb. load is placed

against the belt (see figure below).
tighten the mounting bolts on the pump mounting

7.

bracket to the proper torque.

LOOSEN THESE

TWO BOLTS

HYDRAULIC

DRIVE BELT

IDLER PULLEY

HYDRAULIC

BELT PULLEY

Replace hydraulic drive belt as needed

The condition of the hydraulic drive belt should be checked

annually, or after every 25 hours of operation. Replace

the belt if it is cracked, worn, frayed, or stretched.
to replace the belt:

Proper belt tension is a deflection of 7/16" for a 20 lb. load

SPAN LENGTH

FORCE

20 LBS

7/16" DEFLECTION

5.9 FILL CooLaNT (DIESEL)

Coolant tank for diesel engine

The diesel engine is tested before shipping. In order to test

the equipment the fluid levels are filled. However, before

starting the machine, and every time the engine is started

thereafter, be sure to check the coolant level. If the level

is low, add fluid.
Refer to the engine owner’s manual for coolant information

and maintenance.

5.10 CHaNGE oIL

Check the oil level before each use. Change oil as directed

in the engine owner's manual.
The controller will blink a code every 100 hours as a

reminder to change oil. To reset the controller, see Sec.

7.4.