beautypg.com

12 filling hydraulic fluid, Warning, Englis h – Echo CH8670H Owners Manual v.5 User Manual

Page 25

background image

21

8 INCH TURNTABLE CHIPPER

ENGLIS

h

SERVICE & MAINTENANCE

BEFORE INSPECTINg OR SERVICINg ANy PART OF THIS MACHINE, SHuT OFF POWER SOuRCE,

DISENgAgE THE HyDRAulICS, OPEN SHIElD AND MAkE SuRE All MOVINg PARTS HAVE COME TO A COMPlETE STOP.

WaRNING

5.12 FILLING hYdRauLIc FLuId

Hydraulic pressure controlled by the relief valve is

factory set at 2500 PSI.

NoTE

Hydraulic fluid drives the feed roller. Check the fluid

level daily and fill as needed. The fluid and filter should

be changed and system cleaned if the fluid becomes

contaminated with foreign matter (water, dirt, grease, etc.)

or if the fluid has been subjected to temperatures greater

than the maximum recommended.

loosen the four engine mount bolts and slide engine

7.

towards chipper housing.
Remove the drive belt from the disk shaft pulley.

8.

Remove the bolts attaching the pulley bushing to the

9.

pulley.
Install the bushing push bolts and tighten alternately

10.

one flat at a time to remove the bushing from the

pulley.
Remove the pulley and the pulley bushing.

11.

loosen the bearing spacer bolt and remove the bearing

12.

spacer.
loosen the two bearing set screws.

13.

Remove four bearing mounting bolts and proximity

14.

sensor bracket.
remove bearing and install new bearing with grease

15.

zerk facing engine.
Install the four bearing mounting bolts with washers

16.

through the proximity sensor bracket, bearing, bearing

mount bracket and frame. Torque to 75 ft lb.
tighten the two bearing set screws.

17.

install the bearing spacer tight against the bearing and

18.

lock in place.
Adjust the proximity sensor to within 1/32” to 1/16” from

19.

bearing spacer bolt head.
Place pulley bushing on shaft.

20.

Place pulley on bushing.

21.

Align pulley with engine pulley using a straight edge.

22.

Alternately tighten bushing bolts 1 flat at a time.

23.

Install drive belt on pulley.

24.

Install large idle pulley if previously removed.

25.

lower engagement handle to engage drive belt.

26.

Alternately turn each of the belt tension bolts clockwise

27.

an equal number of turns until the belt deflection at the

center of the belt is 7/16” when a 20 lb load is placed

against the belt (figure 5.6)
Check pulley alignment using a straight edge and

28.

adjust the appropriate belt tension screw if required.
Tighten the four engine mount bolts to the appropriate

29.

torque.
tighten engine tie bolt.

30.

Verify blade to anvil clearance is 1/16 to 1/8” on all

31.

blades.
tilt access cover over disk.

32.

replace the two 3/8 inch retaining bolts holding

33.

the access cover to the main frame assembly and

tighten.

Handle pressurized hydraulic fluid carefully. Escaping

pressurized hydraulic fluid may penetrate your skin

causing serious injury. This fluid may also be hot

enough to burn. Serious infection or reactions can

develop if immediate proper medical treatment is not

administered.

WaRNING

The hydraulic pump requires premium hydraulic fluids

containing high quality rust, oxidation, and foam inhibitors.

These include premium turbine oils, API CD engine oils

per SAE J183, M2C33F or g automatic transmission

fluids meeting Allison C-3 or Caterpillar TO-2, and certain

specialty agricultural tractor fluids.

In the unlikely event that the oil is completely drained

from the hydraulic system, oil must be added and any air

bubbles must be purged from the system. To do this:

Clean all system components (reservoir, fittings,

1.

etc.).

Fill the hydraulic reservoir.

2.

start the engine and run at the lowest possible rPM.

3.

As you purge air from the unit, the oil level in the

4.

reservoir will drop and bubbles may appear in the fluid.

Refill the reservoir as necessary.

Run the feed roller in both directions for several

5.

minutes until any remaining air purges from the unit.

Refill the reservoir as necessary.

Shut down the engine, check for and correct any

6.

fluid leaks, and check the reservoir level. Add fluid

if necessary. The hydraulic pump is now ready for

operation.

This manual is related to the following products: