SECTION 2 - SERVICE PROCEDURES - LOAD SENSING SYSTEM
2-8
– JLG Lift –
3124289
2.5 GROUND CONTROL MODULE
(DRIVABLE VERTICAL LIFTS ONLY)
The following instructions are supplemental to the DVL/
DVSP Operators and Service manuals and show addi-
tional features on the ground control module for machines
equipped with the Load Sensing System.
Programming
The Ground Control Module must be programmed to
detect the Load Sensing System before the LSS will func-
tion properly.
1. Enter the Service Programming Mode (Level 2 -
Password) at the Ground Control Module (Refer to
the machine’s Service Manual for instructions).
2. Enter the Program menu and scroll through the item
list to find and set the LSS programming item range
as shown following:
LCD Display
When an overload warning is detected the following alter-
nating screens are displayed on the Ground Control Mod-
ule LCD screen:
2.6 PLATFORM CONTROL CONSOLE
(DRIVABLE VERTICAL LIFTS ONLY)
Table 2-3. Ground Control Module Programming -
Drivable Lifts ONLY.
PROGRAMMABLE
ITEM
FACTORY
PRESET
SETTING RANGE
Enable Detection of
LSS
2
0 - Detection Disabled
1 - Enabled - Warning Disables
Platform Functions Only
2 - Enabled - Warning Disables
Platform and Ground
Control Functions
LCD Display Symbols
1. Drive and Lift Up/Down Functions - Disable Indicators
2. Description of Warning - Platform Overloaded
Note: When the Overload condition is indicated the LCD screen will
alternate between the text and symbol display modes.
00000.0
1
2
Platform Console LED Indicators
1. The platform console LED bar will flash 9 (Nine) LEDs
to indicate a Platform Overload condition.
–+