21 machine personality settings, Machine personality settings -26 – JLG 2658E3 Service Manual User Manual
Page 38

SECTION 2 - PROCEDURES
2-26
– JLG Lift –
3120878
2.21 MACHINE PERSONALITY SETTINGS
Table 2-2. Machine Personality Settings
PERSONALITY
MIN
MAX
DRIVE-ACCEL
0.5 SEC
5.0 SEC
DRIVE-DECEL
0 SEC
5.0 SEC
DRIVE CREEP
1%
25.0%
DRIVE SPEED MAX (LOW)
50%
100%
DRIVE SPEED MAX (HIGH)
50%
100%
*ELEVATION MAX
*0%
*40%
*POSI-TRAC TIME
*0 Sec
*60 Sec
*HIGH DRIVE OVERCURRENT
*50 Amp
*200 Amp
HIGH DRIVE TIME OUT
0 Sec
25 Sec
LIFT ACCEL
0.5 Sec
5.0 Sec
LIFT DECEL
0.0 Sec
1.5 Sec
LIFT CREEP
1%
25%
LIFT UP MAX
50%
100%
MAX DOWN
30%
100%
DECK ACCEL
0.5 Sec
5.0 Sec
DECK DECEL
0 Sec
5 Sec
DECK CREEP
1%
25%
DECK EXT MAX
0
100%
DECK RET MAX
0
100%
STEER STATIC
20%
50%
STEER (DRIVE COMP)
0
35%
GROUND LIFT UP MAX
0%
100%
GROUND LIFT DOWN
0%
100%
GROUND DECK OUT
0%
100%
GROUND DECK IN
0%
100%
*JLG strongly recommends that these settings not be changed. Changing these settings may adversely
affect the performance of your machine.
NOTE: Personality settings can be adjusted within the adjustment range in order to achieve optimum machine
performance.