2 emergency recovery system test, 2 emergency recovery system test -2 – JLG 4017 Eccupped for Platform Operator Manual User Manual
Page 124

Section 7 - Additional Checks
7-2
31200028
7.2
EMERGENCY RECOVERY SYSTEM TEST
The Emergency Recovery System (ERS) is available in case of emergency, engine
or hydraulic failure. To check this feature, perform the following:
“Shut-Down Procedure” on page 3-4.
2. Make sure the emergency stop switch in the cab is not depressed.
3. Open the engine cover.
4. Push the enable button on the ERS control panel and verify the green light
illuminates.
5. While depressing the enable button rotate the lift/lower then the extend/retract
switches briefly to ensure proper operation.
6. Close and secure the engine cover.
If any function does not operate properly, the machine must be removed from
service and repaired before continued operation.
8
OW1150
OZ1500
ERS
This manual is related to the following products: