SECTION 1 - SAFETY PRECAUTIONS
1-4
– JLG Lift –
3120742
• Maintain a clearance of at least 10 ft (3m) between any
part of the machine and its occupants, their tools, and
their equipment from any electrical line or apparatus
carrying up to 50,000 volts. One foot additional clear-
ance is required for every additional 30,000 volts or
less.
DO NOT MANEUVER MACHINE OR PERSONNEL INSIDE PROHIB-
ITED ZONE (MSAD). ASSUME ALL ELECTRICAL PARTS AND
WIRING ARE ENERGIZED UNLESS KNOWN OTHERWISE.
Tipping Hazards
• Ensure that the ground conditions are adequate to
support the maximum tire load indicated on the
machine. Do not travel on unsupported surfaces.
• The user should be familiar with the driving surface
before driving. Do not exceed the allowable sideslope
and grade while driving.
• Do not elevate platform or drive with platform elevated
while on a sloping, uneven, or soft surface. Ensure
machine is positioned on a firm, level and uniformly
supported surface before elevating platform or driving
with the platform in the elevated position.
• Before driving on floors, bridges, trucks, and other sur-
faces, check allowable capacity of the surfaces.
• Never exceed the maximum work load as specified on
the platform. Distribute loads evenly on platform floor.
Keep all loads within the confines of the platform,
unless authorized by JLG.
Table 1-1.Minimum Safe Approach Distances (M.S.A.D.)
Voltage Range
(Phase to Phase)
MINIMUM SAFE APPROACH
DISTANCE
in Feet (Meters)
0 to 300V
AVOID CONTACT
Over 300V to 50 KV
10 (3)
Over 50KV to 200 KV
15 (5)
Over 200 KV to 350 KV
20 (6)
Over 350 KV to 500 KV
25 (8)
Over 500 KV to 750 KV
35 (11)
Over 750 KV to 1000 KV
45 (14)