SECTION 3 - TROUBLESHOOTING
3121103
– JLG Sizzor –
3-3
No electrical signal being sent to lift down control
valve cartridge
Refer to electrical troubleshooting table
Lift down control valve cartridge not functioning
properly
Repair or replace lift down control valve cartridge
Lift cylinder not functioning properly
Repair or replace lift cylinder
Platform raises and lowers erratically
Hydraulic system low
Replenish hydraulic oil as required
Restricted or broken hydraulic line or fitting
Clean, repair or replace line or fitting
Lack of lubricant on lift cylinder attach pins
Lubricate as required (Refer to lubrication chart)
Counterbalance valve on lift cylinder improperly
adjusted or not functioning properly
Replace valve
Control valve not functioning properly
Repair or replace valve
Sizzor arm pins not properly lubricated
Lubricate as necessary
Worn seals in lift cylinder
Replace seals
Cylinder not functioning properly
Repair or replace lift cylinder
Platform drifts down
Manual lowering valve not functioning properly
Repair or replace valve
Worn seals in lift cylinder
Replace seals
Holding valve on lift cylinder not functioning prop-
erly
Repair or replace holding valve
High drive does not operate below set height
Damaged wiring on limit switch
Repair or replace wiring
Damage limit switch
Replace limit switch
Table 3-1. Platform Assembly - Troubleshooting
TROUBLE
PROBABLE CAUSE
REMEDY