SECTION 3 - TROUBLESHOOTING

3121103

– JLG Sizzor –

3-3

No electrical signal being sent to lift down control
valve cartridge

Refer to electrical troubleshooting table

Lift down control valve cartridge not functioning
properly

Repair or replace lift down control valve cartridge

Lift cylinder not functioning properly

Repair or replace lift cylinder

Platform raises and lowers erratically

Hydraulic system low

Replenish hydraulic oil as required

Restricted or broken hydraulic line or fitting

Clean, repair or replace line or fitting

Lack of lubricant on lift cylinder attach pins

Lubricate as required (Refer to lubrication chart)

Counterbalance valve on lift cylinder improperly
adjusted or not functioning properly

Replace valve

Control valve not functioning properly

Repair or replace valve

Sizzor arm pins not properly lubricated

Lubricate as necessary

Worn seals in lift cylinder

Replace seals

Cylinder not functioning properly

Repair or replace lift cylinder

Platform drifts down

Manual lowering valve not functioning properly

Repair or replace valve

Worn seals in lift cylinder

Replace seals

Holding valve on lift cylinder not functioning prop-
erly

Repair or replace holding valve

High drive does not operate below set height

Damaged wiring on limit switch

Repair or replace wiring

Damage limit switch

Replace limit switch

Table 3-1. Platform Assembly - Troubleshooting

TROUBLE

PROBABLE CAUSE

REMEDY