Faults on the T 65 basic ULTRA-TURRAX
®
Cause
Effect
Solution
Power supply failure
The unit cannot be switched on at
Checking the power supply should be perfor-
the main switch.
med by authorised personnel.
The equipment has switched itself off.
Precautionary measure:
Check the power supply
Stand not in position (if the
The unit cannot be switched on at
Move the stand into position.
stand safety limit switch is
the main switch.
connected)
The equipment has switched itself off.
Precautionary measure:
Check the position of the stand
Overload
The overcurrent limit switch has
Remedy the overload, e.g.:
switched the unit off.
- the viscosity of medium is too high
- Solids jamming the stator/rotor
- Dispersing element defective (blocked).
If none of these causes was the cause of the problem, a fault other than those described must have occurred and the unit must be
checked by an authorised person.
Error codes T 65 digital ULTRA-TURRAX
®
If a fault occurs with the unit, proceed as follows:
Switch off the unit at the main switch (A)
Carry out corrective measures
Restart the device
All error codes are displayed with the legend "trip", i.e. the word "trip" is displayed alternating with the relevant error code.
Error
Cause
Effect
Solution
code
lt.AC Motor overload
Device off
Reduce the load by reducing the speed.
Overloads are especially liable to occur with
high-viscosity media and at high speeds.
Oht1 Overtemperature
Device off
Switch the unit off and allow it to cool down,
try reducing the load or the operating cycle.
OI.AC Overcurrent at the frequency
Device off
Reduce the load by reducing the speed. If this
inverter
error appears even when idling with no load,
the frequency inverter is defective. Consult
the Service Engineer.
OU
Overvoltage at the frequency
Device off
Check the mains power cable values and the
inverter
power supply.
Note: High-frequency noises during operation of the T 65 digital ULTRA-TURRAX
®
may to some extent originate from the frequency
inverter, depending on the design. They certainly do not indicate a defect within the unit.
Note: The green and red LEDs around the "Speed setting" rotary knob (E) are not relevant to the T 65 digital ULTRA-TURRAX
®
unit.
Any faults are shown exclusively on the display (F).
Note: If any error codes other than those listed above appear on the display please switch the unit off and on again at the main
switch (A). If the error code persists please contact the IKA
®
Service Department.
If the actions described fail to resolve the fault or another error code is displayed then take one of the following steps:
- Contact the IKA
®
service department