PERFORMANCE DATA
COOLING EXTENDED PERFORMANCE TABLE
HEATING EXTENDED PERFORMANCE TABLE
-10–20
HEATING EXTENDED PERFORMANCE TABLE 30–60
*At 75°F entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80°F entering dry bulb.
See Legend and Notes on page 17.
602A060 (5 TONS)
Temp (F)
Air Ent
Outdoor Coil
(Edb)
Indoor Entering Air—CFM/BF
1750/0.07
2000/0.12
2250/0.15
Indoor Entering Air—Ewb (F)
72
67
63*
62
72
67
63*
62
72
67
63*
62
85
TC
67.9
61.8
56.5
55.5
68.9
63.3
57.9
57.2
69.6
64.4
59.1
59.0
SHC
35.1
44.4
42.2
52.5
36.8
47.7
45.2
56.4
38.4
50.7
48.2
59.0
kW
5.25
5.22
5.16
5.15
5.27
5.22
5.19
5.18
5.28
5.22
5.22
5.22
95
TC
65.3
59.0
53.4
52.5
66.5
59.8
54.7
54.3
67.3
61.1
55.8
56.3
SHC
34.3
43.3
40.8
50.9
36.2
46.1
43.8
54.3
38.0
49.5
46.7
56.3
kW
5.78
5.74
5.63
5.61
5.78
5.77
5.66
5.66
5.79
5.76
5.69
5.70
105
TC
62.8
55.2
50.5
49.5
64.0
57.1
51.5
51.6
64.1
57.5
52.5
53.7
SHC
33.6
41.5
39.7
49.4
35.6
45.3
42.4
51.6
36.9
47.9
45.3
53.7
kW
6.34
6.27
6.21
6.14
6.36
6.32
6.18
6.19
6.35
6.35
6.21
6.24
115
TC
58.7
52.3
46.9
47.1
59.9
53.1
48.1
49.0
60.7
54.1
49.4
50.9
SHC
31.8
40.6
38.0
47.1
33.9
43.4
40.9
49.0
35.8
46.5
44.3
50.9
kW
6.94
6.78
6.72
6.64
6.95
6.90
6.75
6.77
6.96
6.94
6.69
6.82
602A060 (5 TONS)
Temp (F)
Indoor Air Cfm (std)
Air Temperature Entering Outdoor Coil (F db at 70% rh)
Ent Indoor Coil
-10
0
10
17
20
60
1750
TC
22.7
21.0
27.8
25.6
33.3
30.5
36.6
33.4
39.4
35.7
kW
3.82
4.08
4.15
4.21
4.27
2000
TC
23.2
21.4
28.5
26.3
33.5
30.9
36.8
33.6
40.0
36.3
kW
3.81
3.94
4.12
4.17
4.21
2250
TC
23.4
21.6
28.6
26.3
33.8
31.1
37.2
33.9
40.5
36.7
kW
3.79
3.92
4.04
4.10
4.15
70
1750
TC
21.1
19.5
26.4
24.3
32.8
30.1
35.8
32.6
38.8
35.2
kW
4.02
4.27
4.48
4.55
4.63
2000
TC
21.3
19.7
27.3
25.1
32.9
30.2
36.0
32.8
39.1
35.5
kW
4.01
4.26
4.42
4.49
4.57
2250
TC
21.5
19.9
28.4
26.1
33.1
30.4
36.2
33.0
39.3
35.7
kW
4.00
4.21
4.49
4.49
4.50
80
1750
TC
18.1
16.7
21.1
19.4
32.2
29.5
35.1
32.0
38.0
34.4
kW
4.12
4.48
4.83
4.94
5.05
2000
TC
18.3
16.9
22.7
20.9
31.9
29.3
34.9
31.8
38.0
34.4
kW
4.11
4.47
4.77
4.88
4.98
2250
TC
18.5
17.1
25.4
23.4
30.8
28.3
35.1
32.0
39.3
35.7
kW
4.11
4.48
4.69
4.82
4.95
602A060 (5 TONS)
Temp (F)
Indoor Air Cfm (std)
Air Temperature Entering Outdoor Coil (F db at 70% rh)
Ent Indoor Coil
30
40
47
50
60
60
1750
TC
46.1
40.4
52.8
52.8
57.7
57.7
59.4
59.4
64.8
64.8
kW
4.39
4.57
4.62
4.66
4.79
2000
TC
46.7
40.9
53.0
53.0
57.5
57.5
59.1
59.1
64.1
64.1
kW
4.35
4.41
4.50
4.53
4.64
2250
TC
46.7
40.9
52.9
52.9
57.3
57.3
58.6
58.6
63.3
63.3
kW
4.27
4.32
4.41
4.43
4.53
70
1750
TC
45.3
39.7
52.5
52.5
57.2
57.2
59.3
59.3
65.0
65.0
kW
4.81
5.04
5.05
5.09
5.24
2000
TC
45.8
40.1
52.5
52.5
57.3
57.3
59.3
59.3
64.5
64.5
kW
4.76
4.93
4.92
4.96
5.08
2250
TC
45.8
40.2
52.3
52.3
57.4
57.4
59.1
59.1
64.1
64.1
kW
4.65
4.82
4.82
4.85
4.96
80
1750
TC
44.2
38.8
51.2
51.2
56.1
56.1
58.6
58.6
65.0
65.0
kW
5.21
5.51
5.56
5.57
5.73
2000
TC
44.2
38.8
52.1
52.1
56.5
56.5
58.8
58.8
64.9
64.9
kW
5.09
5.39
5.40
5.43
5.57
2250
TC
44.3
38.8
51.6
51.6
56.7
56.7
58.9
58.9
64.7
64.7
kW
4.87
5.32
5.29
5.32
5.45