Chapter 11 – Troubleshooting
56
TB47J – 0075182
Symptom
Engine will not start from lower
controls.
Engine will not start from upper
controls.
Possible Cause
Switches are set wrong. The engine
will not crank.
The start switch was left in the on po-
sition for 30 seconds or longer before
turning it to start.
The main system circuit breaker on
the wiring box has tripped. The en-
gine will not crank.
Switches are set wrong. The engine
will not crank.
Platform foot switch is activated.
The start switch was left in the on
position for 30 seconds or longer be-
fore turning it to start.
Corrective Action
Turn the battery disconnect switch on
and then at the lower controls:
• Turn the master start switch off.
• Pull the emergency stop button
outward.
• Place the control selector switch
in the ground position.
• Place the start switch in the on
position for 5 seconds and then
turn the switch to start.
Turn the start switch back to off, then
to start within 30 seconds.
Push the main system circuit breaker
button back in. If the button pops back
out, refer the problem to a qualified
service technician.
Turn the battery disconnect switch on
and then at the lower controls:
• Turn the start switch off.
• Pull the emergency stop button
outward.
• Place the control selector switch
in the platform position.
• Place the start switch in the on
position.
From the upper controls:
• Turn the start switch off.
• Pull the emergency stop button
outward.
• Place the start switch in the on
position for 5 seconds and the
then turn the switch to start.
Do not step on foot switch while start-
ing the engine.
Turn the start switch back to off, then
to start within 30 seconds.