Snorkel TB47J User Manual
Page 18

Chapter 4 – Safety Devices
14
TB47J – 0075182
Figure 4.5 – Platform
The gates close automatically after entering or exiting
the platform. The gate is part of the guardrail system and
must be securely fastened after entering the platform.
Lanyard Anchors
Two lanyard anchors for fall restraint anchorage are pro-
vided below the upper controls at the front of the platform
(refer to Figure 4.4).
Note
The lanyard anchors are not for lifting or tying the ma-
chine down.
All personnel in the platform must connect their fall re-
straint device to a lanyard anchor before raising the plat-
form. Do not use the aerial platform for personal fall ar-
rest anchorage.
Ground Fault Circuit Interrupter
The electrical power outlet at the platform contains a
ground fault circuit interrupter (GFCI) to provide protec-
tion for personnel.
Figure 4.6 – Electrical Power Outlet
Ground Operation Switch
The ground operation switch (refer to Figure 4.1) prevents
boom and platform movement if a control switch on the
lower control panel is accidentally moved.
Hold the switch up to operate the machine from the lower
controls.
Platform Foot Switch
Stepping down on the platform foot switch (refer to Figure
4.4) activates the upper controls.
Figure 4.4 – Platform
The foot switch must be engaged and a control must be
moved to operate the boom, drive, and/or platform from
the upper controls.
Guardrails
The guardrail system includes a top rail, mid rail, and
toeboards around the sides of the platform (refer to Fig-
ure 4.4).
A gravity gate (refer to Figure 4.4) or an optional swinging
gate (refer to Figure 4.5) allows for access to the plat-
form.
Swinging
Gate
Platform Foot
Switch
Mid Rail
Toeboard
Lanyard
Anchors
Gravity
Gate
Top Rail
Electrical
Power Outlet