beautypg.com

Reventative, Aintenance, Heck – Snorkel TM12-sn5000-7351 User Manual

Page 11: Eport

background image

Page 11

TM12 Work Platform

P

REVENTATIVE

M

AINTENANCE

C

HECK

L

IST

COMPONENT

INSPECTION OR SERVICES

INTERVAL

Y

N

R

Battery

System

Check electrolyte level

Daily

Check battery cable condition

Daily

Charge batteries

Daily

Check charger condition & operation

Daily

Check specific gravity

6m

Clean exterior

6m

Clean terminals

6m

Hydraulic Oil*

Check oil level

Daily

Change Filter

6m

Drain and replace oil

2y

Hydraulic

System

Check for leaks

Daily

Check hose connections

30d

Check hoses for exterior wear

30d

Drive Motors

Check for operation and leaks

Daily

Emergency

Down

Check procedure for Emergency Down

Daily

Hydraulic Pump

Check for fitting leaks

Daily

Wipe clean

30d

Check for leaks at mating surfaces

30d

Check mounting bolts for proper torque

6m

Controller

Check condition & operation

Daily

Platform Deck &

Rails

Check fasteners for proper torque

Daily

Check welds for cracks

Daily

Check condition of deck

Daily

Check entry way closure

Daily

Elevating

Assembly

Inspect for external damage, dents, loose

rivets or cracks

Daily

Check chains and sheaves for wear

6m

Chassis

Check cables for pinch or rubbing points

Daily

Check welds for cracks

Daily

Check component mounting for proper

torque

6m

Lift Cylinder

Check for leaks

Daily

Check for proper torque

6m

Entire Unit

Perform pre-operation inspection

Daily

Check for and repair collision damage

Daily

Lubricate

30d

Check fasteners for proper torque

6m

Check for corrosion; remove and repaint

6m

Labels

Check for peeling, missing, or unreadable

labels & replace

Daily

Wheels

Check for loose components

Daily

Steering System

Oil pivot pins

30d

Oil king pins

30d

Check steering cylinder for leaks

30d

Check hardware & fittings for proper torque

6m

COMPONENT

INSPECTION OR SERVICES

INTERVAL

Y

N

R

* NOTE: Use ISO #46 during summer and ISO #32 during winter.

P

REVENTATIVE

M

AINTENANCE

K

EY

I

NTERVAL

Daily=each shift or every day
50h/30d=every 50 hours or 30 days
250h/6m=every 250 hours or 6 months
1000h/2y=every 1000 hours or 2 years
Y=Yes/Acceptable
N=No/Not Acceptable
R=Repaired/Acceptable

P

REVENTATIVE

M

AINTENANCE

R

EPORT

Date: ________________________________________

Owner: ______________________________________

Model No: ____________________________________

Serial No: ____________________________________

Serviced By: __________________________________

Service Interval: _______________________________