Hydraulic oil, Lubrication, Decals – Snorkel TL33-sn1001-1946 User Manual
Page 10

10
l
The ISO#46 grade of hydraulic oil normally used in
UpRight Work Platforms must be replaced with a
grade suitable for these low temperature conditions.
l
When ambient temperatures fall below 65ºF (18ºC)
batteries cannot deliver 220 Ampere hours and so
should be placed on charge as soon after use as
possible. Under such conditions a 4 hour equalize
charge once a week in the early afternoon will
improve state of charge and battery life.
Charging
1.
Check battery fluid level. If electrolyte level is
lower than 3/8 in (10 mm) above plates add
distilled water only. (DO NOT OVERFILL)
2.
Connect battery charger lead to properly
earthed outlet of correct voltage and frequency.
3.
The Charger will turn on automatically after a
short delay. The LED’s will indicate the rate
of charging.
4.
Charger turns off automatically when batteries
are fully charged.
HYDRAULIC OIL
With the Platform fully lowered i.e. stowed, oil should be
visible on the dipstick. If oil is NOT visible, fill the tank
until oil is then visible on the dipstick. DO NOT fill above
the upper line on the dipstick or when the platform is
elevated.
LUBRICATION
Refer to the Service & Parts Manual for the lubrication
chart and guidelines.
DECALS
Refer to Figure 8 on Pages 12 & 13 for the locations of the
Decals used on the TL33 Work Platform. These Decals
must be present and in good condition before operating the
Work Platform. Be sure to read, understand and follow
these Decals when operating the Work Platform.