beautypg.com

Warning, Caution – Snorkel T46JRT User Manual

Page 20

background image

Operation

18

T40RT/T46JRT – 1430001

Upper Controls

For the upper controls to be operational:

The battery disconnect switch must be in the on

position.

The emergency stop button at the lower controls must

be in the on position.

The control selector switch at the lower controls must

be in the upper control position.

Use the following procedure to operate the machine using

the emergency power system from the upper controls.

1. Pull the emergency stop button outward.

2. Turn the start switch on.

3. Place the drive/boom selector switch in the appropri-

ate position.

4. Step down on the platform foot switch.

5. Hold the engine/emergency power switch in the

emergency power position.

6. Hold the appropriate function toggle switch in the

desired direction.

After Use Each Day

1. Ensure that the platform is fully lowered.

2. Park the machine on a firm level surface, preferably

under cover, secure against vandals, children and

unauthorized operation.

3. Turn the Chassis Key Switch to OFF and remove the

key to prevent unauthorized operation.

Emergency Lowering

Warning

If the platform should fail to lower, NEVER climb down

the elevating assembly.

Stand clear of the elevating assembly while operating

the Emergency Power System.

The emergency power system can be used to operate

the machine from the lower or upper controls.

Caution

The emergency power system is for emergency low-

ering and stowing only. The length of time the pump

can be operated depends on the capacity of the bat-

tery. Do not use this system for normal operation.

Only use the emergency power system if the main power

system fails.

Lower Controls

Use the following procedure to operate the machine using

the emergency power system from the lower controls.

1. Place the battery disconnect switch in the on posi-

tion.

2. Place the key in the control selector switch and turn

it to the lower control position.

3. Pull the emergency stop button outward.

4. Hold the ground operation switch in the on position

while holding the engine/emergency power switch in

the emergency power position.

5. Hold the appropriate function toggle switch in the

desired direction.

This manual is related to the following products: