beautypg.com

Warning – Snorkel S2632E-sn000001 User Manual

Page 19

background image

Table of Contents

17

S1930E/S1932E/S2632E – 1360417

Maintenance

Maintenance

Warning

Always block the elevating assembly whenever it is

necessary to perform maintenance while the platform

is elevated.

Hydraulic Fluid

The hydraulic fluid reservoir is located in the hydraulic

tray. Refer to Figure 5.

Figure 5 – Hydraulic Fluid Reservoir

Note

Never add fluid if the platform is elevated.

Check Hydraulic Fluid
1. Make sure that the platform is fully lowered.
2. Visually check to make sure the fluid is between the

full and add marks.

3. If necessary, remove the filler cap and add fluid of the

proper type. Replace the cap making sure it is tightly

in place. Refer to the machine specifications.

Battery Maintenance

Warning

Hazard of explosive gas mixture. Keep sparks, flame,

and smoking material away from batteries.
Always wear safety glasses when working near

batteries.
Battery fluid is highly corrosive. Thoroughly rinse

away any spilled fluid with clean water.
Always replace batteries with manufacturer approved

replacements.

• Check the battery fluid level daily, especially if the

machine is being used in a warm, dry climate.

• If electrolyte level is lower than 6 mm (¼″) above the

plates add distilled water only. DO NOT use tap water

with high mineral content, as it will shorten battery

life.

• Keep the terminals and tops of the batteries clean.
• Refer to the Service Manual to extend battery life and

for complete service instructions.

Warning

Always use manufacturer approved replacement

parts.

Battery Charging

Charge the batteries at the end of each work shift or

sooner if the batteries have been discharged.

Warning

Charge the batteries in a well ventilated area.
Do not charge the batteries when the machine is near

a source of sparks or flames.
Permanent damage to the batteries will result if

the batteries are not immediately recharged after

discharging.
Never disconnect the cables from the batteries when

the charger is operating.
Keep the charger dry.
1. At the lower controls, turn the start switch to the off

position.

2. Open the battery tray to access the batteries. Remove

the caps from each battery.

3. Visually check the battery fluid level making sure the

level is within 6 mm (¼″) of the bottom of the filler

neck inside each hole. If needed, add distilled water.

4. Tightly replace the caps on each battery and replace

and latch the battery tray covers.

5. Plug the battery charger into a properly grounded

outlet (100-240 volt AC, 50/60 Hz) using a 3 conductor,

1.5 mm (12 gauge) or larger extension cord. The

extension cord must be as short as possible and in

good electrical condition.

Note

The aerial platform will not operate while the battery

charger is plugged in.
6. Visually inspect the battery charge indicator for

proper charging rate. The LED’s are visible on the

battery tray.

• AC Power On (Blue) – indicates that AC power is

applied to the charger.

This manual is related to the following products: