11

S1930E/S1932E/S2632E – 1360417

Operation

Operation

The aerial platform may be operated from either the lower

or upper controls.

Danger

The aerial platform is not electrically insulated. Death

or serious injury will result from contact with, or

inadequate clearance from, an energized conductor.

Do not go closer than the minimum safe approach

distance as defined by ANSI or national safety

regulations.
Pinch points may exist between moving components.

Death or serious injury will result from becoming

trapped between components, buildings, structures,

or other obstacles. Make sure there is sufficient

clearance around the machine before moving the

chassis or platform. Allow sufficient room and time

to stop movement to avoid contact with structures

or other hazards.
The aerial platform can tip over if it becomes unstable.

Death or serious injury will result from a tip-over

accident. Operate the aerial platform on a firm, flat,

level surface. Avoid travel speeds and/or rough

terrain that could cause sudden changes in platform

position. Do not drive or position the aerial platform

for elevated use near any drop-off, hole, slope, soft

or uneven ground, or other tip-over hazard. Do not

operate the aerial plafform in unapproved locations or

wind conditions.
The platform rated work load is the total weight of the

personnel and equipment that may be lifted in the platform.
The work loads are stated on the platform rating placard

at the entrance to the platform.

Danger

The aerial platform can tip over if it becomes

unstable. Death or serious injury will result from a

tip-over accident. Do not exceed the capacity values

indicated on the platform rating placard.
Capacity values indicate the rated lifting capacity and do

not indicate aerial platform stability.
The operator bears ultimate responsibility for ensuring

that the aerial platform is properly set up for the particular

conditions encountered.

Preparing for Operation

Use the following procedure to prepare the aerial platform

for operation:
1. Perform a pre-operation safety and system function

inspection.

2. Close and latch the battery and hydraulic trays.
3. Place the battery disconnect switch in the on

position.

Lower Controls

Only the platform raise and lower functions may be

operated from the lower controls. The lower controls may

be used for initial set up of the aerial platform, and for

testing and inspection.
Use the following procedure to raise or lower the platform

using the lower controls.
1. Pull the emergency stop button outward (refer to

Figure 3).

2. Insert the key into the control selector switch and turn

the switch to the lower controls position.

3. Hold the ground operation switch upward. Hold the

platform raise/lower toggle switch up to raise the

platform and down to lower it.

4. Release the toggle switch to stop movement.

Upper Controls

The upper controls may be used for driving and positioning

the aerial platform while on the job.
Before operating the upper controls, properly set up

the aerial platform as described under Preparing for

Operation.

Warning

The potential for an accident increases from

improperly driving or steering the aerial platform.

Death or serious injury could result from such

accidents. Make sure the upper control panel is at

the front of the platform, hooked on the guardrail,

and hanging inside the platform.


Avoid driving the platform with the upper controls facing

the rear or side of the machine. In this position the machine

is difficult to control because the drive and steer control

movements and their resulting machine movements will

not correspond.
Only operate the upper controls when the panel is at the

front of the platform, hooked on the guardrail inside the

platform, and facing the front of the machine (refer to

Figure 4).
Use the following procedure to operate the aerial platform

from the upper controls:
1. From the lower controls, pull the emergency stop

button outward (refer to Figure 3).

2. Insert the key into the control selector switch and turn

the switch to the lower controls position.

Note

The upper controls will not operate while the control

selector is in the lower position.