Pop-Up PUSH 6 ECO

Operator’s Safety and Maintenance Handbook (v.0.4.0409)

Section 5

MAINTENANCE

Troubleshooting

Problem

Cause

Repair

Platform does not raise

(hydraulic pack motor

not running)

1. Faulty wiring

1. Check the wiring by referring

to the electrical schematic

diagram p.16

2. Battery is disconnected

2. Reconnect the battery

3. Battery charge is insufficient 3. Charge the battery

Platform does not raise

(hydraulic pack motor

running)

1. Faulty adjustment of relief

valve

1. Adjust relief valve

2. Faulty hydraulic pump

2. Replace power pack

3. Insufficient hydraulic oil

3. Add hydraulic oil

Platform creeps

(uncontrolled lowering)

1. Oil leakage in power pack

1. Replace lowering valve

2. Oil leakage from hydraulic

circuit

2. Check hydraulic circuit and

repair

Oil leakage from cylinder

Faulty sealing

Replace sealing

Oil leakage from hydraulic pipes

Insufficient tightening or seal

invalid

Tighten joint again or replace

seal

Oil leakage from air breather

( ller cap)

Excessive quantity of oil

Reduce oil quantity