Chapter 9 – Operation
32
0120843-ANSI PUSH PRO 6,8,10
Upper Controls
.Before operating the upper controls, properly set up the
aerial platform as described under Preparing for Opera-
tion.
Use the following procedure to operate the aerial platform
from the upper controls:
1. From the lower controls, pull the emergency stop
button outward (refer to Figure 9.1).
2. Insert the key into the control selector switch and
turn the switch to the upper controls position (refer
to Figure 9.1).
Note
The upper controls will not operate while the control
selector is in the lower position.
3. Enter the platform and secure the gate.
4. From the upper controls, turn the emergency
stop button clockwise to the on position (refer to
Figure 9.2).
Figure 9.2 – Upper Controls
5. The platform may be raised and lowered from the
upper controls.
Platform
Use care when entering and exiting the platform to avoid
slipping and/or falling. Securely close the safety gate
when the platform is occupied.
Raising and Lowering
Press and hold the interlock button on the left side of
the upper control box.
• To raise the platform, press and hold the platform raise
button until the desired height is reached.
• To lower the platform, press and hold the platform lower
button until the desired height is reached.
Lowering Interrupt
When the platform is lowered to about 1.5 m (5′) lower-
ing stops. The platform will not lower for five seconds
regardless of the joystick position. Release the platform
lower button to reset the lowering function, then con-
tinue to lower the platform.
Pull-Out Trays
Batteries and hydraulic components are enclosed in
Pull out tray (refer to Figure 9.3) on the right side of the
chassis.
Figure 9.3 – Pull Out Tray
Danger
The aerial platform can tip over if it becomes
unstable. Death or serious injury can result from
a tip-over accident. Do not open the tray when the
platform is elevated.
To open the tray, lift up on the tray latch and pull the
tray open.
Emergency
Stop Button
Lift
Selector Buttons
Interlock
Button
Latch
Tray