beautypg.com

Snorkel MB26 User Manual

Page 21

background image

2. Operation & Specifications

2 - 11

EMERGENCY SITUATIONS

In any emergency situation, the immediate action is to push the red “Emergency Stop” button.

This will instantly cut of all electrical power to the controls. The button must be twisted in a

clockwise direction in order to recommence control.
However, the switch should be reset only when it is safe to do so.
If the Continuous Audible warning alarm sounds, normal control functions will cease to operate.

This will be due to the following problem;
• The Tilt Sensor has been activated

EMERGENCY LOWERING (BY HAND)

!

!

During manual emergency lowering,

extreme care must be taken to

ensure that the person carrying out the task is not struck by the jib or

platform structure.

C A U T I O N

Should the machine become inoperable when elevated request a person on the ground to lower

the platform using the emergency lowering valves. Lower the mast structure before lowering the

jib/platform structure.

NOTE:

Lower the masts fully before lowering the jib structure.

Figure 8: Emergency Lowering - Mast Valve Figure

Locate the red lever behind the mast cover

inspection door on the left hand side of the

machine. By pushing the lever up, the mast

will descend fully under gravity. Releasing the

spring-loaded lever will cease this operation

immediately if required.

9: Emergency Lowering - Jib Valve

The Jib may be manually lowered by operating

the manual release valve located between the

Jib Structure.

MANUAL ROTATION

1. Lower the masts and jib fully before manually slewing the assembly. Press the Emergency Stop

Button to prevent inadvertent powered motion.

2. Locate the opening behind the front right drive wheel. Apply a 23 mm socket wrench with

extension bar to the shaft and turn to rotate the elevating assembly. (Turning the front wheel fully

to one side will facilitate this operation).

This manual is related to the following products: