Snorkel M2639J-sn350+ User Manual
Page 16
Page 10
4 O
PERATION
OF
THE
P
LATFORM
C
ONTROLS
C
ONTROLS
AND
I
NDICATORS
The pre-operation safety checks should be carried out prior to operation. These checks
are detailed in the previous section. Operators who follow these guidelines will become
familiar with the controls and indicators on the machine.
This section summarises the controls and indicators in tabular form and provides more
detailed information.
E
LEVATING
& L
OWERING
THE
W
ORK
P
LATFORM
Before operating the M2032/2639J Work Platform it is imperative that the pre-operation
Safety Inspection has been completed and any deficiencies have been corrected. The
operator must also be fully trained in the use of this machine.
Before beginning any operation, the following checks should be carried out.
NOTE: Chassis controls are for service use only.
1. Enter the Platform through the entrance at the rear of the M2032/2639J and ensure
that the drop bar is in position. Raise and lock the entry step by means of the pedal in
the platform.
2. Before using the machine all local Safety Regulations involving helmets and restraining
devices should be observed. Safety harness lanyards, not exceeding 1 metre in length,
should be attached to anchor points in cage floor.
3. Ensure that the ‘ON/OFF Key Switch on the Upper Control Box is turned to the ‘ON’
position and both emergency stop buttons are off (twist clockwise if necessary).
4. Check the Display L.E.D. is illuminated. If not, the battery may need recharging.
5. Check if the audible alarm sounds due to un-level ground. None of the functions can
work if the machine is not level.
W A R N I N G
!
!
DO NOT operate the machine from the upper controls until the
platform entrance drop-bar is in the fully lowered position and your
safety harness has been fitted and attached.
W A R N I N G
!
!
ENSURE that no other persons are within 1 metre of the machine.
Be aware of the pothole protection bar hazard on both sides of the
machine.
LOOK up and around for obstructions before performing the lift or
drive functions.
DO NOT overload the platform.
DO NOT operate within 3 metres of any electrical power cables.
THIS WORK PLATFORM IS NOT ELECTRICALLY INSULATED.