beautypg.com

Emergency controls – Snorkel AB48HSRT-sn4701+ User Manual

Page 25

background image

23


Emergency Lowering a, method two.

In the event of a power failure, the emergency

lowering hand pump can be operated from the

driver side foot well, choosing between the boom

controls and slewing functions on the 3 way

operation valve. To operate the hand pump, simply

insert the lever into the pump shaft, then lower the

lever to a convenient position to start pumping


The boom lowering control can be chosen by rotating the valve handle to

the vertical position.





Move a lever to the required direction of movement and continue to hold in

this position while operating the hand pump to lower the basket.


















Vigorous pumping is required to lower the machine.

EMERGENCY CONTROLS