beautypg.com

Battery maintenance engine maintenance, Notice, Warning – Briggs & Stratton 8000 Watt Portable Generator User Manual

Page 19

background image

19

• Use a soft bristle brush to loosen caked on dirt or oil.

• Use a vacuum cleaner to pick up loose dirt and debris.

Battery Maintenance

Other than float charging, described elsewhere, no
maintenance is required for the starting battery. Keep the
battery and terminals clean and dry.

IMPORTANT: Battery charging should be performed in a dry
location, such as inside a garage.

Engine Maintenance

Oil

Oil Recommendations

We recommend the use of Briggs & Stratton Warranty
Certified oils for best performance. Other high-quality
detergent oils are acceptable if classified for service SF, SG,
SH, SJ or higher. DO NOT use special additives.

Outdoor temperatures determine the proper oil viscosity for
the engine. Use the chart to select the best viscosity for the
outdoor temperature range expected.

* Below 40°F (4°C) the use of SAE 30 will result in hard starting.

** Above 80°F (27°C) the use of 10W30 may cause increased oil

consumption. Check oil level more frequently.

NOTE: Synthetic oil meeting ILSAC GF-2, API
certification mark and API service symbol with
“SJ / CF ENERGY CONSERVING” or higher, is an
acceptable oil at all temperatures. Use of synthetic
oil does not alter required oil change intervals.

Checking Oil Level

Oil level should be checked prior to each use or at least
every 5 hours of operation. Keep oil level maintained.

1. Make sure generator is on a level surface.

2. Clean area around oil fill, remove oil cap/dipstick and

wipe dipstick with clean cloth. Replace and tighten
dipstick. Remove and and check oil level.

3. Verify oil is at “Full” mark (A) on dipstick. Replace and

tighten oil cap/dipstick.

Adding Engine Oil

1. Make sure generator is on a level surface.

2. Check oil level as described in Checking Oil Level.

3. If needed, slowly pour oil into oil fill opening to the

Full” mark on dipstick. DO NOT overfill.

4. Replace and tighten oil cap/dipstick.

NOTICE

Improper treatment of generator can damage it and
shorten its life.

• DO NOT expose generator to excessive moisture, dust, dirt, or

corrosive vapors.

• DO NOT insert any objects through cooling slots.

WARNING

Unintentional sparking can result in fire or
electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR
• Disconnect the spark plug wire from the spark plug and place

the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK
• Use approved spark plug tester.

• DO NOT check for spark with spark plug removed.

NOTICE

Overfilling with oil may cause the engine to not start, or
hard starting.

• DO NOT overfill.

• If over the FULL mark on dipstick, drain oil to reduce oil level to

FULL mark on dipstick.

A